Information according to Regulation (EU) No. 66/2014
Measurement and calculation methods according to EN 61591:1997+A1:2006+A2:20
11+A11:2014+A12:2015
Item number
10033116, 10033117, 10034151, 10034152
Description Symbol Value Unit
Annual Energy Consumption AEC
hood
15,3 kWh/Year
Time increase factor f 0,8
Fluid Dynamic Efciency FDE
hood
32,2
Energy Efciency Index EEI
hood
36,8
Measured air ow rate at best
efciency point
Q
BEP
255,1 m³/h
Measured air pressure at best
efciency point
P
BEP
204 Pa
Maximum air ow Q
max
601,7 m³/h
Measured electric power input at
best efciency point
W
BEP
44,8 W
Nominal power of the lighting
system
W
L
9 W
Average illumination of the lighting
system on the cooking surface
E
middle
101 Lux
Measured power consumption in
standby mode
P
o
0,48 W
Measured power consumption
off mode
P
s
0 W
Sound power level L
WA
60 dB
Contact details Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany