Falmec FDDOW36T6SGB Downdraft Hood with Touch Control + 24H

User Manual - Page 15

For FDDOW36T6SGB.

PDF File Manual, 36 pages, Read Online | Download pdf file

Loading ...
Loading ...
Loading ...
15
ENGLISH
In case of:
devices tted with cables without a plug: the type of plug to use is
a ''standardised'' one. The wires must be connected as follows: yel-
low-green for grounding, blue for neutral and brown for the live. The
plug must be connected to an adequate safety socket.
xed equipment not provided with a power supply cable and plug,
or any other device that ensures disconnection from the electrical
mains, with an opening gap of the contacts that enables total discon-
nection in overvoltage category III conditions.
Said disconnection devices must be provided in the mains power
supply in compliance with installation regulations.
The cable must not be cut o by the switch.
The Manufacturer declines all responsibility for failure to comply with
the safety regulations.
FUMES DISCHARGE
EXTERNAL EXHAUST HOOD SUCTION
In this version the fumes and vapours are discharged
outside through the exhaust pipe.
To this end, the hood outlet tting must be connected
via a pipe, to an external output.
The outlet pipe must have:
a diameter not less than that of the hood tting.
a slight slope downwards (drop) in the horizontal sections to prevent
condensation from owing back into the motor.
the minimum required number of bends.
the minimum required length to avoid vibrations and reduce the
suction performance of the hood.
You are required to insulate the pipes if it passes through cold envi-
ronments.
In the presence of motors with 800m
3
/h or higher, a check valve is
present to prevent external air owing back.
ASSEMBLY INSTRUCTIONS
Intended only for qualied personnel
The hood can be installed in various congurations.
The generic assembly steps apply to all installations; for
each case, follow the specic steps provided for the re-
quired installation.
OPERATION
WHEN TO TURN ON THE HOOD?
Switch on the hood at least one minute before starting to cook to direct
fumes and vapours towards the suction surface.
After cooking, leave the hood operating until complete extraction of all
vapours and odours. By means of the Timer function, it is possible to set
auto switch-o function which will allow the hood to turn o automat-
ically after 15 minutes of operation.
WHICH SPEED IS TO BE SELECTED?
1st speed: maintains the circulation of clean air with low electricity
consumption.
2nd speed: normal conditions of use.
3rd speed: presence of strong odours and vapours.
4th speed: rapid disposal of odours and vapours.
WHEN SHOULD THE FILTERS BE WASHED OR REPLACED?
The metal lters must be cleaned every 30 hours of operation.
The active carbon lters must be replaced every 3-4 months, depend-
ing on the use of the hood.
For further details refer to the “MAINTENANCE” section.
TOUCH PUSHBUTTON PANEL
ON/OFF (Blue led steady on)
Motor on/o and Speed 1
ON/OFF (blue led ashing)
If pressed for more than 3 seconds, it activates the 24h cycle
(1h ON -> 3h
OFF -> 1h ON)
the function deactivates if:
- The motor turns o (key )
- After 24h
Speed 2 activation
Speed 3 activation
Speed 4 activation for a few minutes only
Light on/o
TIMER (Red LED ashing)
Auto switch-o after 15 min.
The function deactivates (red LED o) if:
- The motor turns o (key ).
- The speed is changed.
With hood open:
FILTER ALARM (red LED steady on)
Anti-grease lter maintenance after approximately 30 hours
of operation.
Press the meter for 3 seconds to reset.
With hood closed:
If pressed for over 3 seconds, the hood opens for maintenan-
ce.
No control active.
To close the hood, press ( ) again for 3 seconds.