12 INSTALLATION
NOTE
• For closet installation, with a door, minimum
ventilation openings in the top and bottom of
the door are required. Louvered doors with
equivalent ventilation openings are acceptable.
• Minimum vent opening for built-in installation is
31.5 sq. in. (200 cm
2
.)
Closet Ventilation Requirements
Closets with doors must have both an upper and
lower vent to prevent heat and moisture build-up
in the closet.
One example shown uses vent grilles in the door.
a Upper vent opening with a minimum opening
of 48 sq. in. (310 cm
2
) must be installed no
lower than 6 ft. (185 cm) above the floor.
b Lower vent opening with a minimum opening
of 24 sq. in. (155 cm
2
) must be installed no
more than one foot above the floor.
Ambient Temperature
• Temperature must be between 50 ℉ (10 °C) and
95 ℉ (35 °C).
• If the ambient temperature is too low or high,
performance may be affected.
• Do not install in direct sunlight or where the
temperature may fall below 32 ℉ (0 °C).
Electrical Connection
• Do not use an extension cord or 2-outlet
adapter.
• Do not overload the outlet with more than one
appliance.
• Connect the appliance to an earthed socket in
accordance with current wiring regulations.
• The appliance must be positioned close to
outlets and the plug should be easily accessible.
WARNING
• The power cord must be plugged into an
appropriate outlet that is installed and
grounded/earthed in accordance with all local
codes and ordinances.
Dimensions
inch mm
A
2 25 1/2 2 650
B
2 18 2 455
C
2 10 2 250
D
2 74 3/8 2 1889
E
2 74 1/8 2 1875
F
2 15 3/4 2 400
G
2 2 2 50
H
2 24 7/8 2 630
I
2 19 2 485
J
2 2 2 50
K
2 1 2 25
L
2 1 3/16 2 30
B
I H
E
D
F
G
J
K
L
L
7.6 cm7.6 cm
7.6 cm7.6 cm