Dimplex QXD1500 QXD 1.5kW Quartz Halogen Radiant Heater

Installation and Operating Instructions

For QXD1500. Additionally, the document applies to other Dimplex models: QXD3000, QXD4500

PDF File Manual, 8 pages, Read Online | Download pdf file

QXD1500 photo
background
Models Covered:
QXD1500, QXD3000 and QXD4500 08/50866/4 Issue 4
Installation and Operating Instructions
IMPORTANT SAFETY ADVICE
The installation of these appliances must
always be carried out by a competent
electrician and be in accordance with the
current wiring regulations and relevant
Building Regulations.
The radiated heat from the heater is
considerable and must be taken into account
when locating the heater. Ensure that the
heater is not used in close proximity to the
skin or eyes.
Always isolate the heater from the supply
before undertaking any maintenance work
on the appliance.
The QXD range of heaters are designed for
internal use only. They are not rated as ame-
proof and must not be used when ammable
dusts, gases, or vapours, etc. are likely to be
present in the atmosphere. If in doubt, advice
should be sought from the Health and Safety
Executive inspectors or local re ofcers.
Quartz lamps are extremely fragile and must
be handled with extreme care at all times.
Avoid touching the surface of the quartz
sleeve with bare ngers. If the sleeve is
accidentally touched remove the nger print
with a soft cloth moistened with methylated
spirits.
This heater must not be located immediately
above or below a xed socket outlet or
connection box.
The life expectancy of the halogen lamps
in normal operating conditions is over 3000
hours.
The heater must be installed in a location that
is free from vibration.
WARNING:This appliance must be earthed.
Means for disconnection from the electrical
supply must be incorporated in the xed
wiring in accordance with the wiring rules.
WARNING: This heater is not equipped with
a device to control room temperature. Do not
use this heater in small rooms when they are
occupied by persons not capable of leaving
the room on their own, unless constant
supervision is provided.
This appliance can be used by children
aged from 8 years and above and
persons with reduced physical, sensory or
mental capabilities or lack of expierience
or knowledge if they have been given
supervision or instruction concerning the
use of the appliance in a safe way and
understand the hazards involved. Children
shall not play with the appliance. Cleaning
and user maintenance shall not be made by
children without supervision.
Children of less than 3 years should be kept
away unless contiuously supervised. Children
aged from 3 years and less than 8 years shall
only switch on/off the appliance provided
that it has been placed or installed in its
intended normal operating position and they
have been given supervision or instruction
concerning the use of the appliance in a safe
way and understand the hazards involved.
Children aged from 3 years and less than 8
years shall not plug in, regulate and clean
the appliance or perform user maintenance.
CAUTION: Some parts of this product can
become very hot and cause burns. Particular
attention has to be given where children and
vunerable people are present.
These instructions should be read carefully and retained by the user.
Loading page 2...
Loading page 3...
Loading page 4...
Loading page 5...
Loading page 6...
Loading page 7...
Loading page 8...

Other documents for Dimplex QXD1500

The following documents are available:
User Manual Specification Other Documents Photos

Specifications

See other models: OPH20 OPH13 IAB15A CFCH CXD2000V

Installation and Operating Instructions - Transcript

  • Page 1 - English - : Models Covered QXD1500 QXD3000 and QXD4500 08508664 Issue 4 Installation and Operating Instructions IMPORTANT SAFETY ADVICE The installation of these appliances must always be carried out by a competent electrician and be in accordance with the current wiring regulations and relevant Building Regulations The radiated heat from the heater is considerable and must be taken into account when locating the heater Ensure that the heater is not used in close proximity to the skin or eyes Always isolate the heater from the supply before undertaking any maintenance work on the appliance The QXD range of heaters are designed for internal use only They are not rated as ame proof and must not be used when ammable dusts gases or vapours etc are likely to be present in the atmosphere If in doubt advice should be sought from the Health and Safety Executive inspectors or local re ofcers Quartz lamps are extremely fragile and must be handled with extreme care at all times Avoid touching the surface of the quartz sleeve with bare ngers If the sleeve is accidentally touched remove the nger print with a soft cloth moistened with methylated spirits This heater must not be located immediately above or below a xed socket outlet or connection box The life expectancy of the halogen lamps in normal operating conditions is over 3000 hours The heater must be installed in a location that is free from vibration WARNINGThis appliance must be earthed Means for disconnection from the electrical supply must be incorporated in the xed wiring in accordance with the wiring rules WARNING This heater is not equipped with a device to control room temperature Do not use this heater in small rooms when they are occupied by persons not capable of leaving the room on their own unless constant supervision is provided This appliance can be used by children aged from 8 years and above and persons with reduced physical sensory or mental capabilities or lack of expierience or knowledge if they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Children of less than 3 years should be kept away unless contiuously supervised Children aged from 3 years and less than 8 years shall only switch onoff the appliance provided that it has been placed or installed in its intended normal operating position and they have been given supervision or instruction concerning the use of the appliance in a safe way and understand the hazards involved Children aged from 3 years and less than 8 years shall not plug in regulate and clean the appliance or perform user maintenance CAUTION Some parts of this product can become very hot and cause burns Particular attention has to be given where children and vunerable people are present These instructions should be read carefully and retained by the user
  • Page 2 - English - : QXD3000 All dimensions in mm QXD4500 UNIVERSAL BRACKET MOUNTING ANGLE ADJUSTMENTS 4 FIXING HOLES SPECIFICATIONS The Dimplex QXD range is available in 12 and 3 lamp models with outputs of 15kW 30kW and 45kW respectively The three lamp models are supplied as dual voltage units and are suitable for use on 230240V and 415V 3N supplies General Data Model No No of Lamps Rating kW Voltage V Weight kg QXD1500 QXD3000 QXD4500 230240 230240 230240 Material and Finished Body Casing Low carbon steel powder coated Reectors 1080 SIA 998 Alum Electrochemically brightened specular nish DIMENSIONS QXD15001500ND1500G All dimensions in mm
  • Page 3 - English - : WIRING DIAGRAMS QXD1500 QXD3000 QXD4500 a External connections for 230240V 1pH b External connections for 415V 3N GY GREENYELLOW R RED B BLue LINKS MUST BE FITTED HEATER WIRING AS OPPOSITE CABLE ALL MODELS 25MM SILICONE INSULATED LINKS MUST BE REMOVED
  • Page 4 - English - : 1 Location The siting of the heaters should be such as to allow an even and uninterrupted distribution of radiation to the areas to be heated Heaters are most effective when the beam angle is inclined down at an angle of 30º to 45º to the vertical 2 Mounting IMPORTANT When deciding upon the best location consideration must be given to the following requirements a Avoid structures liable to vibration eg crane gantries which could otherwise adversely affect lamp life b The lamps are designed to operate within 5º of the horizontal plane It is very important to ensure that the heater is mounted horizontally otherwise the operating life of the lamp could be impaired c Allow a minimum of 05 metre clearance between the top of the heater and the ceiling Dimension C on the appliance rating label Allow a minimum of 15 metre clearance between the edge of heater and the adjacent wall facing that edge Dimension B on the appliance rating label d Ensure appliance is mounted the correct way up so that it can be tilted down but not up Mounting height Allow the following mounting height between the base of the heater and the oor Dimension A on the appliance rating label Model No Rating kW Min Height m Recommended Height m QXD1500 QXD3000 QXD4500 2535 Note If more than one heater is to be installed ensure that the lamps of adjacent heaters are more than 35 metres apart Mounting Brackets Heaters are supplied with a universal bracket which may be xed through the mounting holes to any suitable structure The bracket allows the heater to be inclined to the required angle from the vertical and permits the heater to be swivelled laterally It is recommended that when inclined from the vertical and swivelled care is taken to ensure that the lamps are still horizontal WARNING THESE HEATERS ARE DESIGNED TO BE WALL MOUNTED ONLY THEY MUST NOT BE CEILING MOUNTED THEY MUST NOT BE MOUNTED IN A ROOM CONTAINING A BATH OR SHOWER DO NOT MOUNT HEATERS CLOSER THAN 35 METRES FROM CURTAINS OR SIMILAR SOFT FURNISHINGS 3 Electrical Supplies Wiring to the heater must be installed in compliance with the requirement of the wiring regulations and any local or insurance regulations All heaters are suitable for use on 230240V single phase supplies The 45kW model is supplied as a dual voltage unit and is also suitable for use on 415V three phase supplies Heaters must be protected by fuses to the following rates Model No Input Rating kW Current Rating A Fuse Rating A 230240V 415V 230240V 415V QXD1500 QXD3000 QXD4500 625Ph 10Ph Wiring between the heater and the spur outlet or isolation switch must be in a heat resisting cable eg butyl rubber or high temperature PVC insulated Sufcient slack cable must be left to allow for angular adjustment of the heater body An allpole isolating switch with a minimum separation of 3mm in each pole must be tted adjacent to the heater to facilitate local isolation If miniature circuit breakers are to be used to avoid nuisance tripping due to the high in rush at switch on a type 3 or C rated MCB with a tripping coefcient of 710 times rated current should be used Any other switching device should be Tungsten lamp load rated 45kW heaters must be connected in accordance with the instructions When connecting to 415V three phase supplies the links must be removed from the terminal block When using the heater on 230240V supplies the Danger 415V notice should be removed from the terminal cover Always ensure that the cable grip is tightened
  • Page 5 - English - : 4 Coverage for Spot Heating Applications The area heated by a Quartz Halogen Heater depends on the height and the angle at which the heater is mounted For 30 Heater Mounting Angle Area Covered Height² x 266 Average Width of Beam Height x 20 Throw of Beam Height x 133 For 45 Heater Mounting Angle Area Covered Height² x 572 Average Width of Beam Height x 22 Throw of Beam Height x 26 Note Area covered width and throw of beam are measured at oor level The table below indicated throw and spread measured 1 metre above oor level which may be a more appropriate measurement for some applications The following tables show the recommended mounting heights for three typical average intensity requirements Average Radiant Intensity on Heated Area Wm² QXD1500 QXD3000 QXD4500 Height m Throw m Spread m Height m Throw m Spread m Height m Throw m Spread m Angled 30 from vertical 150 29 25 38 37 36 54 44 44 67 200 27 22 33 34 31 47 39 38 58 250 25 20 30 31 28 42 36 34 52 Angled 45 from vertical 150 23 34 29 29 49 42 33 56 50 200 21 29 24 26 41 35 30 52 44 Note 1 Intensity is average intensity in Wm² based on Wattage of heater and area covered and measured on a horizontal plane 1m above the oor level 2 Heater mounting heights are in metres and are above oor level Those marked are minimum mounting heights for the particular heater model 3 Throw and spread gures are in metres
  • Page 6 - English - : 5 COMMISSIONING 1 Checks on the electrical installation should include earth continuity and insulation tests and must be undertaken by a competent person 2 Ensure that all the electrical connections at the lamps and the terminal rails have been made correctly that they are tight and that there is no loose or frayed wire 3 Replace and secure the terminal cover and replace and secure the front panel 4 Check that the mounting bracket is securely xed in the vertical position such that the lamps remain in a horizontal plane at all angles of heater displacement 5 Roughly align the heaters and tighten the adjusters 6 Switch on the heaters and check that the lamps are all operating If time or temperature controls are tted check these for correct and safe operation by reference to the suppliers instructions 7 Make any adjustments that are necessary to give an even spread of heat over the required area This may be done simply by perception of the heating effect or by using the distribution of visible light either at night or by darkening the room Hand over Hand over these instructions and make sure the user is familiar with all aspects of operation and safety including the need for regular cleaning and an annual inspection In the event of the premises being unoccupied then leave heaters switched off and isolated from the electrical supply Leave instructions adjacent to the electricity meter 6 MAINTENANCE Since the Dimplex Quartz Heater contains no moving parts little maintenance is required beyond cleaning and lamp replacement It is however essential that the heater is not operated with accumulation of dust or dirt on the lamps or reectors as this can cause a build up of heat and eventual damage For this reason the heater must be inspected regularly depending upon conditions and at least at yearly intervals Before undertaking any maintenance work on the heater due attention must be paid to the following 1 Always disconnect the heater from the electricity supply before attempting to work on or near it 2 Always ensure a safe means of access using an access tower or properly supported ladder 3 Some types of quartz lamps run with an internal pressure in excess of atmospheric pressure and while construction is very strong there is a slight risk of shattering If it is necessary to examine a bare lamp whilst in operation then a protective screen must be used 4 Allow adequate time for the lamps and body casing to cool before attempting to work on the heater 7 LAMP REPLACEMENT WARNING BEFORE UNDERTAKING THIS TASK ENSURE THE HEATER IS DISCONNECTED FROM THE ELECTRICITY SUPPLY 1 Detach heater from its mounting position 2 Unscrew the front panel by loosening the corner xing screws and then lift front panel clear 3 Disconnect the wires to the old lamp by removing the lock nuts retaining the terminal ends adjacent to the lamp clips Do not slacken the screws as this could disturb the internal wiring 4 Remove the lamp by gently releasing the ends from the spring clips Keep the lamp secure and do not twist the ends or apply undue force IMPORTANT Release and retain the high temperature cable ties from the element wires These must not be substituted 5 Before removing the new lamps from its protective packing it is important to be aware that quartz lamps are fragile and must be handled with care at all times Avoid touching the surface of the quartz sleeve with bare ngers If the sleeve is accidentally touched remove the nger print with a soft cloth moistened with methylated spirit 6 Hold the lamp rmly but gently at each end and offer up to the spring mounting clips The wire leads should face towards the front of the heater Push the lamp fully into the clips taking care to keep it square Do not twist the ends or apply undue force If either end of the lamp will not easily engage in the spring clips remove the lamp and gently ease the spring 7 The wire from each end of the lamp must be connected to the threaded connector ON THE SAME CLIP AS THE LAMP END With the outside not loosened insert the spade between the two outside nuts and tighten rmly 8 When the lamp has been tted check that the electrical connections have been correctly made Reuse the same cable tie to tether the element wires in place Ret the front panel checking that wires are not trapped
  • Page 7 - English - : INSPECTION AND CLEANING 1 Check that all the lamps are functioning If any thermostatic or time controls are tted ensure that the supply is on before checking lamps Any failed lamps should be replaced see lamp replacement Remove any accumulated dirt and check wiring and connections 2 Clean the lamps and reectors using a mild detergent solution and soft cloth Do not use any abrasive or caustic cleaners Dry with a soft cloth Avoid touching either the quartz lamp sleeve or the aluminium reector with bare ngers If they are accidentally touched remove any nger prints using a soft cloth moistened with methylated spirit 3 Check that the lamps are properly located in the spring retaining clips and that they have not been disturbed by cleaning The lamps should be pushed fully back into the clips for applying light pressure on the end caps only SAFETY IN OPERATION The heater is operated by simply switching on the electrical supply or if used in conjunction with a control system then the suppliers instructions must be observed ALWAYS disconnect the heater from the supply before attempting to work on or near it NEVER operate the heater with a high accumulation of dust or dirt on the lamps or reector or with a damaged or corroded reector NEVER use the heater outside or in contact with water NEVER use the heater where ammable dusts gases or vapours etc are likely to be present in the atmosphere NEVER operate the heater in close proximity to the skin or eyes NEVER allow materials which could be damaged or ignited by the radiated heat to be placed in close proximity to the heater NEVER cover the heater even when it is switched off ALWAYS refer to these instructions before attempting to dismantle the heater AFTER SALES SERVICE Your Dimplex Quartz Heater is guaranteed for one year from the date of purchace We undertake to exchange or repair free of charge within this period any part found to be defective due to a manufacturing fault Should you require after sales service please get in touch with the supplier through whom you purchased the appliance or the contact number on your Warranty leaet Please do not initially return a faulty appliance or part of an appliance as this may result in transit damage andor delay in providing service Let us know your difculty quoting the model number and series letter of the appliance We will then take the appropriate action
  • Page 8 - English - : The product complies fully with the requirements of the current EMC Directive 2004108EC the Low Voltage Directive 200695EC and the RoHS EU Directive 200295EC Dimplex A division of GDC Group Ltd Millbrook House Grange Drive Hedge End Southampton Hampshire SO30 2DF c GDC Group Ltd All rights reserved Material contained in this publication may not be reproduced in whole or in part without prior permission in writing of GDC Group Limited Customer Services UK 0845 600 5111 Fax 01489 773050 Email customerservicesgdcgroupcouk Republic of Ireland Tel 01 842 4833