Loading ...
Loading ...
Loading ...
4441
16. Technical data
INSTALLER: Please leave these instructions with the user.
DATA BADGE LOCATION: Inside base drawer of cavity.
COUNTRY OF DESTINATION: USA, Canada.
Connections
Electric 240 V 60 Hz
Gas ½” NPT at rear left-hand side
Maximum total electric load 240 V (including oven
fans, lights, etc.):
Note: The maximum input at any time is
given as the fanned grill, which is all top elements and the fan.
5.1 kW, 21 A
Dimensions
Overall height minimum 35 ⁄” (91cm) maximum 36 ⁄” (93.7cm)
Overall width 43 ⁄” (1092cm); see ‘Positioning of Cooker’.
Overall depth 28 ⁄” (723 mm)
Minimum space for cooktop 31½” (800 mm)
Weight (unpacked) 385 lbs (175 kg)
Ratings
Oven
Fan element 2.5 kW
Top element 1.2 kW
Browning element 1.15 kW
Bottom element 1.0 kW
Gas Hob
Bypass
Screw*
Natural Gas 4” WC Propane Gas 10” WC
Input Orice Input Orice
Center burners 49 17,000 btu/hr 205 17,000 btu/hr 118
Larger burners 38 12,000 btu/hr 150 12,000 btu/hr 99
Right-hand front burner 31 6,000 btu/hr 112 6,000 btu/hr 68
* The valves in this range are tted with adjustable bypass screws.The range is supplied with the bypass screws set for Natural gas.For LPG conversion the
bypass screws must be screwed all the way down.
ArtNo280-0090 Drawer Cavity & Badges
Loading ...
Loading ...
Loading ...