Tempest I Use, Care, and Installation Guide
TEMPEST I
UNDERCABINET
PRO
Installation Instructions
Mounting the Hood
For Mounting to a Wall (FIG. C)
1. Select preferred duct location (vertical or
horizontal).
2. Begin installation by removing the bae filters.
3. Temporarily position the range hood in the
desired mounting location. Measure and
mark the mounting holes, duct and electrical
locations with a pencil.
4. Drill/cut out required openings.
5. Fasten hood onto wall with screws provided.
6. Install electrical.
7. Install duct work and duct tape.
8. Reinstall bae filters.
9. Power up hood and check for leaks around
duct tape.
FIG. C
2. Bae
filters