ELECTRICAL CONNECTION
"The installation must conform to the standard directives".
The manufacturer declines all responsibility for any damage that
may be caused by unsuitable or unreasonable use.
Warning :

shown on the electricity meter, the adjustment of the circuit-
breaker, the continuity of the connection to earth to the installation
and that the fuse is suitable.

a socket with a plug with earth, or via an omni pole cut-out
switch .
If the appliance has a socket outlet, it must be installed so that
the socket outlet is accessible.
The manufacturer cannot be held responsible for any accidents
resulting from the use of an appliance which is not connected
to earth, or with a faulty earth connection continuity.

to 
Warning! This appliance must be earthed. In the absence of
adequate earthing you will notice that when touching the
metal parts of your appliance an electrical dispersion can be
felt due to the presence of a radio interference suppressor.

power cord is not supplied with this T
a terminal block that enables you to choose the correct connection
for the particular power supply.
The terminal block is located at the back of the Trio.
To open the terminal block :
. Locate the two tabs on the sides,
. place the screwdriver blade on the front of the tab, insert it (1)
and press down (2)
. Lift the cover off.
Terminal block
x 3 bars shunts
To connect :
. unscrew the cable grip,
. pass the cable through the cable grip,
. strip the insulation off the end of the each wire and connect them
to the according to the numbers shown in the table as well as
the "bars shunts".
Example of connection in monophase
1- Put in the
bars shunts
2- Put in
the wires
3- Pass the cable
through the cable grip
Caution: incorrect tightening can cause dangerous heating
risks for the power supply cable.
-F
3 G 2,5 mm
2
Monophase
230-240V
~


2 Phase
Shunt 1-2
Shunt 2-3
5 Neutral
Shunt 4-5
T Earth

 T

L

T
make a
bridge with
a shunt bar
F,
-F or,
4 G 2,5 mm
2
-F or,

5 G 1,5 mm
2
Three phases
230-240V3~
Three phases
380-415V3N~
1 Phase
Shunt 1-2
3 Phase
Shunt 3-4
5 Phase
T Earth
1 Phase
2 Phase
3 Phase
5 Neutral
Shunt 4-5
T Earth
L2
L3
INSTALLATION
   
finished, tighten the cable clamp and close the cover.
Installing a domestic appliance can be a complicated operation which if not carried out correctly, can seriously affect
consumer safety.
It is for this reason that a professionally qualified person should undertake the task who will carry it out in accordance with
the technical regulations in force.
In the event that this advice is ignored and the installation is carried out by an unqualified person, the manufacturer declines
all responsibility for any technical failure of the product whether or not it results in damage to goods or injury to individuals.
In case of installation of the cooker on a base, measures have to be taken to prevent the appliance slipping from the base
itself