Loading ...
Loading ...
Loading ...
VIZIO RP56 User Guide
040330 48
Status LEDs
There are two status LEDs on the front of the DLP TV.
Normal Operation
State Power LED Lamp LED Description
AC off Not lit Not lit AC power not connected
Standby mode Green Not lit AC power is connected and the DLP TV is
in standby mode.
Warm-up/Cool down
mode
Green Flashing AC power is connected and the power
button has just been turned on or off.
Operation mode Green Green AC power is connected, the power button
has been pressed and the lamp has
warmed up.
Error Codes
Error Code Power LED Lamp LED Description
21 Flashes green
twice, then
orange once.
Not lit One of the cooling fans has failed. See
"support" on page 51.
32 Flashes green
three times,
then orange
twice.
Flashing Indicates lamp trouble or failure. The DLP
TV will automatically shut down and restart
itself. If this does not solve the problem,
see "support" on page 51.
52 Flashes green
five times,
then orange
twice.
Not lit Indicates hardware error. Power off the
DLP TV, wait one minute, and then restart
the DLP TV. If this does not solve the
problem, see "support" on page 51.
Loading ...
Loading ...
Loading ...