Loading ...
Loading ...
Loading ...
12
GAS SUPPLY REQUIREMENTS
NOTE: The gas service to the dryer must conform with local codes and ordinances
and the latest edition of the National Fuel Gas Code, ANSI Z223.1 or in Canada,
CAN/CGA B149.1.
Natural Gas
•
The dryer is equipped for use with Natural gas.
LP (Liquid Propane) Gas
•
The dryer can be converted for use with LP gas.
•
Conversion to LP gas must be made by a qualied technician.
Gas Supply Line
•
The gas supply line should be ½" (1.3 cm) pipe and must have an individual
manual shuto valve installed within 6 ft (183 cm) of the dryer in accordance with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada with the Natural
Gas and Propane Installation Code, B149.1.
•
The shuto valve should be easy to reach for opening and closing.
•
A ⅛" NPT minimum plugged tapping, accessible for test gage connection, must
be installed immediately upstream of the gas supply connection to the dryer.
•
The supply line should terminate with a ⅜" NPT are adapter tting.
a ½" NPT Gas Supply Line
b Gas Shuto Valve
c ⅛" NPT Minimum Plugged Tapping
d ⅜" NPT Flare Adapter Fitting
B
C
D
A
GAS SUPPLY CONNECTION REQUIREMENTS
This dryer must be connected to the gas supply line with a listed exible gas
connector that complies with the standard for connectors for gas appliances, ANSI
Z21.24 or CSA 6.10.
Flexible stainless steel gas connector:
•
If local codes permit, use a new exible stainless steel gas connector (Design
Certied by the American Gas Association or CSA International) to connect your
dryer to the rigid gas supply line. Use an elbow and a ⅜" are x ⅜" NPT adapter
tting between the stainless steel gas connector and the dryer gas pipe, as
needed to prevent kinking.