User Manual Broan ANKE60302SS NonDuct Recirculating Kit: For 30 Inch Hoo

Documents for Broan ANKE60302SS

The following documents are available:
User Manual Photos
ANKE60302SS photo
ANKE60 SERIES NON-DUCT KIT INSTALLATION INSTRUCTIONS
DIRECTIVES DINSTALLATION DU KIT DE RECIRCULATION DE SÉRIE ANKE60
I
NSTRUCCIONES PARA LA INSTALACIÓN DEL CONJUNTO SIN TUBOS DE LA SERIE ANKE60
ENGLISH
READ AND SAVE THESE INSTRUCTIONS
INSTALLER
:
LEAVE THIS INSTRUCTION SHEET WITH THE HOMEOWNER
CAUTION
Remove protective plastic film covering the non-duct kit flue
before installing it.
Additional installers are recommended because of the large
size and weight of the non duct kit flue and the hood.
THIS KIT CONTAINS:
(1) S
ERVICE PARTS BAG (PA RT N O. SV08351) INCLUDING:
(8)
NO. 8-10 X 1/2” SCREWS, (20) NO. 8 X 3/8" SCREWS (EXTRA
SCREWS PROVIDED FOR LARGER HOODS), (4) NO. 8-32 X 1/2” SCREWS
(1) NON-DUCT KIT FLUE (2) OR (4)* CHARCOAL FILTERS
(2) OR (4)* CHARCOAL FILTER SUPPORTS
* (2) FOR 30” AND 36” WIDTH HOODS OR (4) FOR 42” AND 48” WIDTH HOODS
WHEN PLANNING AN INSTALLATION, THE OVERALL HEIGHT OF THE NON-DUCT KIT FLUE
AND THE HOOD SHOULD BE CONSIDERED
. THE MINIMUM HOOD DISTANCE ABOVE
COOKTOP MUST NOT BE LESS THAN
24’’. A MAXIMUM OF 30” ABOVE COOKTOP IS
RECOMMENDED FOR BEST CAPTURE OF COOKING IMPURITIES. DISTANCES OVER 30”
ARE AT THE INSTALLER AND USERS DISCRETION.
1
2
3
RECIRCULATION CENTER OF WOOD CENTER OF WOOD
KIT WIDTH STRIP LOCATION (A) STRIP LOCATION (B)
30’ 13
3
8 10”
36’ 16
3
8 10”
42’ 19
3
8 10”
48’ 22
3
8 10”
NOTE: FOR CABINETS WITH RECESSED
BOTTOM
, AT TACH 4 WOOD FILLER
STRIPS CUT TO LENGTH (NOT
INCLUDED), AS SHOWN BESIDE.
SEE TABLE BELOW FOR WOOD
FILLER STRIPS LOCATION
.
THE POWER CABLE MUST COME FROM BACK WALL; CUT A 2” SQUARE HOLE IN THE
BACK WALL AT THE LOCATION SHOWN BELOW. RUN POWER CABLE TO INSTALLATION
LOCATION
, OUT OF THE WALL THROUGH THE HOLE IN IT.
RECIRCULATION
KIT WIDTH DIMENSION A
30’ 13”
36’ 16”
42’ 19”
48’ 22”
PLACE THE NON-DUCT KIT FLUE AT ITS
LOCATION
, UNDER THE CABINET. USING
A PEN, MARK THE POSITION OF THE
MOUNTING SCREWS
(SMALL PART OF
THE KEYHOLES
). REMOVE THE NON-DUCT
KIT FLUE AND INSTALL (4) NO. 8-10 X 1/2”
SCREWS LEAVING A 1/8” GAP. PLACE
THE NON
-DUCT KIT FLUE UNDER THE
CABINET
.SLIDE THE FLUE IN POSITION
AND SECURE IT BY TIGHTENING THE
SCREWS COMPLETELY. SECURE THE
FLUE TO THE CABINET WITH THE REST
OF THE NO
. 8-10 X 1/2” SCREWS.
HA0058
HD0268
L
C
AA
BB
HD0267A
L
C
2
/
8
A
2
CUT-OUT OPENING FOR
HOUSE WIRING LOCATION
INSTALL (4) NO. 8-32 X 1/2” SCREWS,
LEAVING A 1/8” GAP, IN FRONT AND
REAR FLANGES
(2 PER FLANGES) OF
THE NON
-DUCT KIT FLUE, AS SHOWN
BESIDE.
NOTE: IT IS A GOOD PRACTICE TO
SEAL THE NON
-DUCT KIT FLUE AND HOOD
HOLES WITH DUCT TAPE
.
HA0059
HOW TO INSTALL CHARCOAL FILTERS
REPLACEMENT IS RECOMMENDED AFTER 30 HOURS OF COOKING
OR SIX MONTHS OF OPERATION. REPLACE MORE OFTEN IF YOUR
COOKING HABITS GENERATES MORE GREASE.
4
PLACE THE HOOD UNDER THE NON-DUCT
KIT FLUE.SLIDE THE HOOD IN POSITION
AND SECURE IT BY TIGHTENING THE SCREWS
COMPLETELY
. FINALIZE MOUNTING THE
HOOD TO THE NON
-DUCT KIT FLUE USING
THE NO. 8 X 3/8” SCREWS (2 PER FLUE
SIDE
, 4 OR LESS AT FRONT, DEPENDING ON
HOOD
/FLUE WIDTH). SEE ILLUSTRATION
BESIDE
. CONTINUE THE HOOD INSTALLATION.
HA0062
FRANÇAIS
LIRE ET CONSERVER CES DIRECTIVES
INSTALLATEUR
:
LAISSER CETTE FEUILLE DE DIRECTIVES
AU PROPRIÉTAIRE
ATTENTION
Retirer la pellicule de plastique protectrice recouvrant le
module de recirculation avant d’installer celui-ci.
Des installateurs supplémentaires sont recommandés lors
de l’installation vu la grande dimension et le poids de la
hotte et du module de recirculation.
CE KIT COMPREND :
(1) S
AC DE PIÈCE (N° SV08351) COMPRENANT :
(8)
VIS N° 8-10 X 1/2 po, (20) VIS N° 8 X 3/8 PO (DES VIS
ADDITIONNELLES SONT FOURNIES POUR LES PLUS GRANDES HOTTES),
(4)
VIS N° 8-32 X 1/2 po
(1) M
ODULE DE RECIRCULATION (2) OU (4)* FILTRES À CHARBON
(2) OU (4)* SUPPORTS POUR FILTRE À CHARBON
*(2) POUR LES HOTTES DE 30 PO ET DE 36 PO DE LARGEUR
OU
(4) POUR LES HOTTES DE 42 PO ET DE 48 PO DE LARGEUR
BROAN-NUTONE LLC; HARTFORD, WISCONSIN WWW.BROAN.COM 800-558-1711
B
ROAN-NUTONE CANADA; MISSISSAUGA, ONTARIO WWW.BROAN.CA 877-896-1119
SV08350
SUITE AU VERSO
LORS DE LA PLANIFICATION DE LINSTALLATION, LA HAUTEUR TOTALE DU MODULE DE
RECIRCULATION ET DE LA HOTTE DOIVENT ÊTRE PRISES EN CONSIDÉRATION
. LA DISTANCE
MINIMALE ENTRE LE BAS DE LA HOTTE ET LA SURFACE DE CUISSON NE DOIT PAS ÊTRE
INFÉRIEURE À 24 PO. UN MAXIMUM DE 30 PO AU-DESSUS DE LA SURFACE DE CUISSON
EST RECOMMANDÉ POUR UNE MEILLEURE ÉVACUATION DES ODEURS DE CUISSON.
UNE DISTANCE DE PLUS DE 30 PO DEMEURE À LA DISCRÉTION DE LINSTALLATEUR ET
DE L
UTILISATEUR.
1
USING NO. 8 X 3/8” PROVIDED
SCREWS
, INSTALL BOTH FILTER SUPPORTS
ON EACH SIDE OF THE INTERNAL
MOTOR
(S). DISCARD EXTRA SCREWS.
2
FOR EACH MOTOR SIDE, POSITION
FILTER OVER ITS SUPPORT AND
ROTATE TO LOCK IT IN PLACE.
HA0060
SCREWS LOCATION
HA0061
NOTE : SI LE FOND DE LARMOIRE EST EN
RETRAIT, Y FIXER 4 BAGUETTES DE
BOIS DE LONGUEUR APPROPRIÉE
(NON INCLUSES), TEL QUIL EST
ILLUSTRÉ CI
-CONTRE. VOIR LE
TABLEAU CI-DESSOUS POUR
L
EMPLACEMENT DES BAGUETTES
DE BOIS
.
HD0268
L
C
AA
BB
LARGEUR EMPLACEMENT DU CENTRE EMPLACEMENT DU CENTRE
DU MODULE DE LA BAGUETTE DE BOIS (A) DE LA BAGUETTE DE BOIS (B)
30 PO 13
3
8 PO 10 PO
36 PO 16
3
8 PO 10 PO
42 PO 19
3
8 PO 10 PO
48 PO 22
3
8 PO 10 PO
Loading ...