13
To set pressure gauge for automatic shut o:
1. With gauge ON, press and hold down [ + ] or [ – ] buttons
to select desired shuto pressure (Fig. 13).
NOTE: Numbers will ash while setting pressure. Holding
buttons down will make the pressure number increase
faster.
2. When desired setting has been selected, begin inating.
Air compressor will shut o once setting is reached.
LED Light (Fig. 14)
The air compressor is equipped with a LED light above the
trigger switch to provide additional lighting for operation in
low light conditions. The LED light will turn on when the power
button [
] is pressed and will stay on for 30 seconds.
Starting/Stopping
1. Place air chuck over valve stem and press down, readout
will appear on gauge (Fig. 13).
2. To turn the air compressor ON, press and hold the power
button [
] below the LCD display (Fig. 12).
NOTE: The digital gauge will automatically shut o when
not in use for 30 seconds or more.
3. With gauge ON, select the desired shuto pressure by
pressing [ + ] or [ – ] buttons (Fig. 13). Once it is set, wait a
few seconds until the current tire pressure displays.
NOTE: Always check and follow the manufacturer’s
recommended pressure, usually located on the door jamb
of your vehicle.
4. Depress the trigger switch (Fig. 15). If inating, the air
pressure will appear on the gauge as the item is being
inated.
5. To turn the compressor OFF, press the trigger switch
6. Remove the thread connector from the tire quickly, and
replace valve stem cap on tire, if required.
mCAUTION! Connector may be hot. Use caution when
removing.
mWARNING! To avoid over-ination of tires, please check
the recommended tire pressure in the vehicle’s owner’s manual. For
bicycle tires, check markings on tire. Use a separate pressure gauge
for a more accurate reading.
mCAUTION! The LCD display must turn on before operating
the air compressor. Please read and understand the instructions
provided in the manual prior to operation.
Lock-On Button
The air compressor is equipped with a lock-on feature, which
is convenient for continuous inating for extended periods of
time.
1. To lock on, depress and hold the trigger switch (Fig. 15).
2. Release the trigger switch and the air compressor will
continue running.
3. To release the lock, press the trigger switch down to stop
(Fig. 15).
Duty Cycle
1. For household use only.
2. The air compressor is designed for occasional use.
Ination over a long period will overheat the air
compressor and may cause damage.
3. The air compressor should not operate for more than 5
minutes at a time, after which it must be switched o
and allowed to cool down for at least 10 minutes before
restarting.