OceanAire 2OAC3612 Deluxe Portable Commercial Air Conditioner

User Manual - Page 20

For 2OAC3612.

PDF File Manual, 36 pages, Read Online | Download pdf file

2OAC3612 photo
Loading ...
Loading ...
Loading ...
DISPLAY FAULTS
LAC……… Low AC line power
AAA……… Failed Air Sensor (unit will not run)
CON……… Empty Condensate Bucket—Units with a bucket
Condensate Pump Over-Flow Alarm—Units with pump
High Pressure Cut-Out—Restricted air flow
correct problem, and re-set unit at HP RESET
TO CHECK THE NUMBER OF HOURS ON THE UNIT
1) Disconnect unit power, and reconnect unit power.
2) When “888” appears in display, push and release the arrow down button
3) The first set of numbers displayed reads thousands of hours:
02 = 2000, 04 = 4000 hours, 00 means less than 1000 hours.
4) The second set of numbers read hours directly:
58 = 58 hours. 742 = 742 hours.
6) Add the 2 number sets together to get total hours.
03 and 486 = 3486 hours. 01 and 59 = 1059 hours.
TOTAL HOURS REPRESENTS COMPRESSOR RUNTIME
MODEL CODE SETTINGS
2OAC12 P1 = 65, P2 = 45
2OAC18 P1 = 80, P2 = 50
2OAC24 P1 = 70, P2 = 50
2OAC36 P1 = 85, P2 = 40
2OAC60 P1 = 85, P2 = 45
2OAC PROGRAM SETTINGS
NOTICE
Program Parameters are NOT controller default values.
They are OceanAire Factory Settings