R600 and HSRL Series LP-Gas Regulators
4
Replace old pigtails. Blow out any debris, dirt or copper
sulfate in the copper tubing and the pipeline.
Apply pipe compound to the male threads of the pipe
before installing the regulator.
Make sure gas ow through the regulator is in the same
direction as the arrow on the body. “Inlet” and “Outlet”
connections are clearly marked.
REGULATOR
APPLICATION
TYPE
NUMBER
CAPACITY
BTU/HR
PROPANE
(1)
INLET
CONNECTION
OUTLET
CONNECTION
OUTLET
PRESSURE
SETTING
3/4-INCH NPT
SCREENED
VENT STANDARD
LOCATION
Second Stage
R622-BCF 875,000 1/2-inch FNPT 1/2-inch FNPT
11 inches w.c. /
27 mbar
Over Inlet
R642-DFF 900,000
3/4-inch FNPT
3/4-inch FNPT
R652-DFF 1,000,000
R622-CFF
1,400,000
1/2-inch FNPT
R622-DFF 3/4-inch FNPT
R622-CFGXA 1,125,000 1/2-inch FNPT
3/4-inch FNPT
18 inches w.c. /
45 mbar
HSRL-BFC
(2)
2,100,000
3/4-inch FNPT
11 inches w.c. /
27 mbar
HSRL-CFC
(2)
1-inch FNPT 1-inch FNPT
Integral
Two-Stage
R632A-BCF
850,000
1/4-inch FNPT
1/2-inch FNPT
11 inches w.c. /
27 mbar
First Stage
(3)
:
Down
Second Stage:
Over Outlet
R632A-HCF FPOL
R632A-CFF 950,000 1/4-inch FNPT
3/4-inch FNPT
R632A-JFF 850,000 FPOL
R632A-BCFXA
850,000
1/4-inch FNPT
1/2-inch FNPT
11 inches w.c /
27 mbar
First Stage
(3)
:
Opposite gauge taps
Second Stage:
Opposite gauge taps
R632A-HCFXA FPOL
R632A-CFFXA 950,000 1/4-inch FNPT
3/4-inch FNPT
R632A-JFFXA 850,000 FPOL
Integral
2 psig / 0.14 bar
Service
R632E-BCH 850,000 1/4-inch FNPT
1/2-inch FNPT
2 psig / 0.14 bar
First Stage
(3)
:
Down
Second Stage:
Over Outlet
R632E-HCH 900,000 FPOL
R632E-CFH
850,000
1/4-inch FNPT
3/4-inch FNPT
R632E-JFH FPOL
2 psig / 0.14 bar
Service
R622E-BCH 1,250,000 1/2-inch FNPT 1/2-inch FNPT
2 psig / 0.14 bar Over InletR622E-DCH 1,500,000
3/4-inch FNPT 3/4-inch FNPT
R652E-DFH 1,400,000
First Stage
R622H-BGK 2,000,000
1/2-inch FNPT
1/2-inch FNPT
5 psig / 0.35 bar
Over Outlet
R622H-BGJ
2,100,000 10 psig / 0.69 barR622H-HGJ
FPOL
R622H-HGJKA
R622H-JGK
2,250,000
3/4-inch FNPT
5 psig / 0.35 bar
R622H-JGJ
10 psig / 0.69 bar
R622H-DGJ 2,400,000 3/4-inch FNPT
1. Capacities Based on:
Second Stage: 10 psig / 0.69 bar inlet pressure and 2 inches w.c. / 5 mbar droop.
Integral Two-stage: 30 psig / 2.1 bar and 2 inches w.c. / 5 mbar droop.
Integral Two psig Service: 30 psig / 2.07 bar and 20% droop.
2 psig / 0.14 bar Service: 10 psig / 0.69 bar inlet pressure and 20% droop.
First Stage: 30 psig / 2.1 bar inlet pressure and 20% droop.
2. Straight globe valve body conguration.
3. Integral First Stage Vent size: 7/16-24 UN thread for 1/4-inch OD copper tube inverted are tting.
Table 2. Capacity, Connection Sizes, and Vent Orientation
Installation Location
The installed regulator should be adequately
protected from vehicular trafc and damage from
other external sources.
Install the regulator with the vent pointed vertically
down, see Figure 2. If the vent cannot be installed
in a vertically down position, the regulator must be
installed under a separate protective cover. Installing