Always ensure that a sufficient supply of fresh air is guaranteed and that the air can circulate.
An air supply / extractor box alone does not ensure compliance with the limit value.
Safe operation is only possible when the negative pressure in the room where the appliance is located does
not exceed 4 Pa (0.04 mbar). This can be achieved when the air required for combustion can flow through
openings that are not closable, for example in doors, windows, in conjunction with an air supply / extractor box
or through other technical measures. In any case, consult a qualified chimney sweep who can assess the entire
ventilation of your house and propose appropriate measures for adequate ventilation.
If the hood is used exclusively in the recirculation mode, unrestricted operation is possible.
WARNING
Fire hazard from flying sparks. Only install equipment on a fireplace for solid fuels (for ex-
ample, wood or coal), if a closed, non-removable cover is available.
Control Panel and Controls
Control Panel
Controls and Functions
ON/OFF button
Touch this button, the indicator light on, and the screen displays
[1], indicating the motor is working at speed 1. Touch this bouton
again and the motor stops working.
Speed increase button
When the hood is ready to work, touch this button and the screen
displays [1], indicating the motor is working at speed 1. The wor-
king speed will be increased each time it is touched, and the
number of the screen displays 1, 2, 3 accordingly. Speed [3] is the
highest speed.
Speed decrease button
When the hood is working, touch this button, the working speed-
will be decreased each time it is touched, and the number of the
screen displays 3, 2, 1 accordingly. Speed [1] is the lowest speed.
Light button Touch this button to turn the light on/off.