29
EN
Information according to Regulation (EU) No. 66/2014
Measurement and calculation methods according to EN 61591:1997+A1:2006+A2:20
11+A11:2014+A12:2015
Item number
10034112, 10034113
Description Symbol Value Unit
Annual Energy Consumption AEC
hood
59,4 kWh/Year
Time increase factor f 1,2
Fluid Dynamic Efciency FDE
hood
22,6
Energy Efciency Index EEI
hood
66,9
Measured air ow rate at best
efciency point
Q
BEP
307,7 m³/h
Measured air pressure at best
efciency point
P
BEP
346 Pa
Maximum air ow Q
max
580,5 m³/h
Measured electric power input at
best efciency point
W
BEP
130,6 W
Nominal power of the lighting
system
W
L
6 W
Average illumination of the lighting
system on the cooking surface
E
middle
108 Lux
Measured power consumption in
standby mode
P
o
- W
Measured power consumption
off mode
P
s
0,4 W
Sound power level L
WA
72 dB
Contact details Chal-Tec GmbH, Wallstraße 16, 10179, Berlin, Germany