36” ALL GAS
RANGES
www.hestanhome.com phone 888.905.7463
3375 E. La Palma Ave., Anaheim, CA 92806CONTACT US:
GAS REQUIREMENTS : ⁄” NPT gas connection.
Minimum gas supply is 7” water column for natural
gas and 11” for propane. Operating pressure at the
manifold is 5” water column for natural gas and 10”
for propane. All units require a regulated gas
supply. (included)
ELECTRICAL REQUIREMENTS
:
110/
120V, 60Hz, 15 amps
KRG
364GD-NG/-LP 36” Range 4 Burner with Griddle
15 Amp
15 Amp 490
490
KRG
365-NG/-LP 36” Range 5 Burner 36” 24-1/2”
142, 000
157, 000
36” 24-1/2”
ALL
Models
Description
W (in.) D (in.)
Total
BTU’s (NG)
Circuit
Breaker Req
Griddle
BTU
Cutout Dimensions
Approx
SHP WT (lbs)
15,000
--
Hestan Indoor products are approved for indoor
use only. Hestan Commercial Corporation reserves the
right to change materials and specications without
notice. Specify type of gas when ordering.
RANGE
MODEL
w
v
(min)
KRG365 36” [91.4]
36” [91.4]
30” [76.2]
KRG364GD 30” [76.2]
W
3”
7.6
5”
12.7
24”
61
V
12”
30.5
19”
48.3
9-1/2”
24.1
6”
15.2
5”
12.7
2-1/2”
6.4
RECOMMENDED
GAS SHUT-OFF
VALVE LOCATION
ELECTRICAL
SUPPLY
LOCATION
120V
G
E
FINISHED
FLOOR
MIN. CLEARANCE
TO NEAREST
COMBUSTIBLE
SIDE SURFACE
48-5/16”
122.7
3”
7.6
24-11/16”
62.7
6”
15.2
LOCATION OF GAS
AND ELECTRICAL
ON FLOOR
ISLAND
TRIM
For Island Trim installations,
counter surface should
have a cantilever surface
meeting the rear of
the Island Trim
MIN. CLEARANCE
TO COMBUSTIBLE
SURFACES WITH
ISLAND TRIM
MAX.
RECESS
DEPTH
COMBUSTIBLE
MATERIALS
COMBUSTIBLE
MATERIALS
INSTALLATION CLEARANCES WITH ISLAND TRIM
SIDE VIEW
FRONT VIEW
NOTES:
* SHADED AREAS INDICATE WHERE COMBUSTIBLE MATERIALS ARE NOT ALLOWED.
* APPLIANCE TOP MUST BE LEVEL OR HIGHER THAN THE ADJACENT COUNTERTOP SURFACES.
* "G" IS GAS CONNECTION ZONE ON REAR WALL. MOUNT SHUT-OFF VALVE AS HIGH AS
POSSIBLE IN THIS ZONE FOR EASY ACCESS WHEN RANGE IS INSTALLED.
* "E" IS ELECTRICAL SUPPLY ZONE.
* "V" IS MIN. CLEARANCE TO REQUIRED VENTILATION HOOD.
DIMENSIONS IN BRACKETS [ ] ARE IN CM.
38-3/8 - 36-7/8”
[97.5 - 93.6]
TO COOKING
SURFACE
KRG365
KRG364GD
30-13/16”
78.3
* "W" IS APPLIANCE OPENING.
NOTE: HANDLE END CAPS PROTRUDE 1/8” BEYOND EACH
SIDE OF THE RANGE. ALLOWANCE MAY BE NEEDED FOR ADJACENT DRAWERS OR CABINETRY.
37-1/4 - 35-3/4”
[94.6 - 90.8]
TO APPLIANCE
TOP
021899 REV D
APPLIANCE
TOP
HANDLE
END CAP
COOKING
SURFACE
REF 1.12”
[2.84 cm]
2-5/8”
[6.7]
7” [17.7]
COUNTERTOP
FULL OVERLAY
DRAWER FACE
FULL OVERLAY
CABINET DOOR FACE
1
8
"
[3.2 mm]