9. Sealed System Repair Method of Refrigerator with R600a Refrigerant
9-1.Outline
9-1-1. Safety warnings and cautions before Sealed System Repair
Keep away ame.
There is a risk of re.
Do not store inammable
ether,benzene,alcohol,chemicals,LP
gas,etc.in the refrigerator
There is a risk of
explosion or re.
9-1-2. Checkpoints before Sealed System Repair
Open the Cover ASM,Back-M/C of refrigerator and check the type of refrigerant indicated on a compressor
before starting work.A yellow label is adhered to the compressor for the refrigerator using R600a as refrigerant.
9-1-3. Features of R600a Refrigerant
·
Non-polar natural gas refrigerant (CH(CH3)3)
·
Since R600a is same series as butane gas,there is danger of re when discharged into air at appropriate
concentration (extreme handling is required for sealed system repair of cycle).
Explosion concentration:1.8%~8.4%/Vol.
Burning temperature:494 ° C
9-1-4. Features of R600a Refrigerator
·
With refrigerant quantity of 60%or so for the refrigerator using R134a as refrigerant
·
Large vacuum level at suction pressure (at low pressure side)
·
COMP capacity of the refrigerator using R600a as refrigerant is large by 1.7 times than that of the refrigerator using R134a.
·
Labels as in Figure are displayed at the compressor of a refrigerant for R600a and the back plate of refrigerator.
Be careful about the ventilation during the repair of refrigerator cycle.
R600a refrigerant is inammable,so make sure to remove heat source or ame during the
work.(Smoking is strictly prohibited.)