Loading ...
Loading ...
Loading ...
9
10. INSTALL THE ROUGH-IN PLATE TO THE HOOD (ALL BLOWERS)
Run power cable to installation location. Refer to the instructions included
with the selected blower/rough-in kit (sold separately) for details on
installing the rough-in plate. Attach blower plate to the studs at the inside,
top or back of hood with 4 no. 10-32 nuts, provided. Install the rough-in
plate so that the wiring box is located on the right side as you are facing
the hood.
For ducting through back of hood, remove existing plate from inside
back of hood and attach it to inside top of hood to cover hole. Secure to
threaded studs with same 4 nuts.
For ducting through top of hood, existing plate remains in place on inside
back of hood.
Connect ducting to adapter and damper or rough-in plate (according to blower model) as you are installing the rough-in plate. Use duct
tape to make all joints secure and air-tight.
BLOWER PLATE
NO.10-32 NUTS
(2 PER SIDE)
HD0048
11. CONNECT THE WIRING (ALL BLOWERS)
Remove wiring cover from rough-in plate and set aside.
Connect BLACK to BLACK, WHITE to WHITE and GREEN or bare wire under GREEN ground screw.
Reinstall wiring cover.
12. INSTALL THE OPTIONAL DECORATIVE FLUE AEWP28 SERIES (ALL BLOWERS)
From inside the hood, attach the optional decorative flue AEWP28 Series to top of hood at sides
and front of hood using no. 8 screws (provided).
HD0050
WARNING
Risk of electric shock. Electrical wiring must be done by qualified personnel in accordance with all applicable
codes and standards. Before connecting wires, switch power off at service panel and lock service disconnecting
means to prevent power to be switched on accidentally.
!
Loading ...
Loading ...
Loading ...