Cadet T522-W Mechanical Non-Programmable Thermostat

OWNER’S GUIDE - Page 3

For T522-W. Also, The document are for others Cadet models: T521*, T522*

PDF File Manual, 4 pages, Read Online | Download pdf file

Loading ...
Loading ...
1. WARNING: All electrical work and
materials must comply with the
National Electric Code (NEC), the
Occupational Safety and Health
Act (OSHA), and all state and
local codes.
2. WARNING: Make sure all wire
connections to the thermostat
are correct and tight to prevent
electrical shorts. Use appropriate
wire to meet NEC and local codes
for rated power consumption.
3. Use copper conductors only.
4. Turn o󰀨 power to heater at main
disconnect panel.
5. Use wire connectors (not included)
for all connections.
6. An electrical outlet box is required.
INSTALLATION INSTRUCTIONS
A. Connect one supply wire to the
red thermostat wire.
B. Connect the black thermostat
wire to one of the heater wires.
C. Connect the remaining supply
wire to the remaining heater wire.
Wrap supply (white) wire with black
tape to identify it as hot!
D. Connect the copper ground
supply wire to the copper wire
going to the heater.
A. Connect the two black thermo-
stat wires to the two loose heater
wires.
B. Connect the two hot supply
wires to the two red thermostat
wires.
Wrap supply (white) wire with black
tape to identify it as hot!
C. Connect the copper ground
supply wire to the copper wire going
to the heater.
SINGLE POLE (2-WIRE) - 240 or 208 VOLT
SINGLE POLE (2-WIRE) - 120 VOLT
DOUBLE POLE (4-WIRE) - 240 or 208 VOLT
A. Connect the hot supply wire to
the red thermostat wire.
B. Connect the black thermostat
wire to the hot supply wire going to
the heater.
C. Connect the remaining neutral
supply wire to the remaining wire
going to the heater.
D. Connect the copper ground
supply wire to the copper wire
going to the heater.
Proceed to OPERATING INSTRUCTIONS.
Proceed to OPERATING INSTRUCTIONS.
Proceed to OPERATING INSTRUCTIONS.
A
B
C
D
A
B
C
D
A
A
B
B
C
FROM
POWER
SUPPLY
TO
HEATER
FROM
POWER
SUPPLY
TO
HEATER
FROM
POWER
SUPPLY
TO
HEATER