Loading ...
Loading ...
Loading ...
49-2000706 Rev. 4 17
INSTALLATION INSTRUCTIONS
Installation Instructions
DETERMINE HOOD, DUCTWORK AND WIRING LOCATIONS
This hood can be installed onto the wall or underneath the
soffit or cabinet.
For installing the hood to soffit or cabinet, refer to page 19
for alternate mounting method.
A wall mounting template is included with the product for
ease of installation. Follow the instructions below if the
template is not being used.
Measure desired distance from the bottom of the hood to
the cooking surface, 24” minimum over electric range or 30”
minimum over gas range and 36” recommended maximum.
Use a level to draw a horizontal line indicating the bottom
of the hood.
Measure 16-3/4” up from the horizontal line indicating the
bottom of the hood. Draw another horizontal line to indicate
the bottom of the installation bar.
Use a level to draw the cooktop or range centerline
location.
For Ceiling Ducting:
If venting out the ceiling, extend the centerline forward on
the ceiling to the back wall.
- Measure 6-1/4” from back wall to mark center point for
an 8” diameter duct hole on the ceiling.
- Cut 8" dia. duct hole on the ceiling.
Venting Through a Soffit or Cabinet:
Follow the same procedure for ceiling ducting to cut the
hole through the top of the soffit or cabinet.
For Ducting Through Rear Wall:
Note: Check to make sure back damper will not interfere
with studs, electrical or plumbing before making cut out.
Back damper accessory UXBDA812 must be purchased
separately for venting through the rear wall.
Measure 3-3/4” up along the centerline from the horizontal
line indicating bottom of the hood.
Make an 10-1/2" x 13-1/4” cut out centered left to right
along the centerline.
House Wiring Location:
The junction box is located inside the hood body on the left
side. See Illustrations for hood knockout locations.
House wiring may enter the junction box from the rear or the
top of the hood on the left side.
To route house wiring through the ceiling, soffit or
cabinet:
Cut a hole approximately 1-1/4” dia. forward on the ceiling
at a distance (X) to the left of the centerline based on table
below.
To route house wiring through the wall:
Note: For back venting, the house wiring must be routed
through the rear knockout so it is hidden.
Measure 15-3/4" from the bottom of the hood and mark
location.
Cut a hole approximately 1-1/4” dia. at the marked location
at a distance (X) to the left of the centerline based on table
below.
Remove top or rear knockout depending on your
installation.
Centerline to Wall
FOR CEILING VENT
DUCTING
Duct Hole
Top of Hood
Installation
Bar
16-3/4”
Bottom of Hood
FOR REAR WALL DUCTING
3-3/4”
6-5/8”
10-1/2”
X
1-1/4”
X
15-3/4”
Rear View
Top View
Models "X"
30" 9-3/4"
36" 10-1/2"
Loading ...
Loading ...
Loading ...