GAS SUPPLY REQUIREMENTS
NOTE: The gas service to the dryer must conform with local codes and ordinances
and the latest edition of the National Fuel Gas Code, ANSI Z223.1 or in Canada,
CAN/CGA B149.1.
Natural Gas
r The dryer is equipped for use with Natural gas.
LP (Liquid Propane) Gas
r The dryer can be converted for use with LP gas.
r Conversion to LP gas must be made by a qualinjed technician.
Gas Supply Line
r The gas supply line should be ½" (1.3 cm) pipe and must have an individual
manual shutoNj valve installed within 6 ft (183 cm) of the dryer in accordance with
the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or in Canada with the Natural
Gas and Propane Installation Code, B149.1.
r The shutoNj valve should be easy to reach for opening and closing.
r A ƌ" NPT minimum plugged tapping, accessible for test gage connection, must
be installed immediately upstream of the gas supply connection to the dryer.
r The supply line should terminate with a ƍ" NPT Ǎare adapter njtting.
½" NPT Gas Supply Line
Gas ShutoNj Valve
ƌ" NPT Minimum Plugged Tapping
ƍ" NPT Flare Adapter Fitting
B
C
D
A
GAS SUPPLY CONNECTION REQUIREMENTS
This dryer must be connected to the gas supply line with a listed Ǎexible gas
connector that complies with the standard for connectors for gas appliances, ANSI
Z21.24 or CSA 6.10.
Flexible stainless steel gas connector:
r If local codes permit, use a new Ǎexible stainless steel gas connector (Design
Certinjed by the American Gas Association or CSA International) to connect your
dryer to the rigid gas supply line. Use an elbow and a ƍ" Ǎare x ƍ" NPT adapter
njtting between the stainless steel gas connector and the dryer gas pipe, as
needed to prevent kinking.