7. Remove (2) screws securing electrical junction box to electronics mounting plate. Remove junction
box shown in FIG. A1.
8. Remove the (2) aluminum mesh filter.
9. Hang hood onto the mounting screws and hand tighten each screw. (FIG. B) Secure third #6 x
1-1/2” screw through inside of hood into wall for extra support shown in FIG. B2.
10. Center and attach duct cover mounting bracket to wall just below the ceiling or sot using (2) #6
x 1” screws.
11. Install duct work and seal duct work with aluminum duct tape. Reinstall electrical junction box with
cable lock and install the electrical shown in FIG. A2.
12. Power up hood and check for leaks around duct tape.
13. Place telescopic duct covers onto hood and extend inner (top) duct cover upwards and secure to
duct cover bracket using (2) M3.5 x 8 screws.
* If using hood in recirculating mode you must secure the air diverter plate onto wall before installing
duct work and duct covers. Turn to the Ductless Recirculation section for more details.