Instructions for the installer
12
5. ADAPTATION TO DIFFERENT TYPES OF GAS
Before performing any cleaning or maintenance work, detach the
appliance from the electrical socket.
The hob has been adjusted for natural gas at a pressure of 1.0kPa.
For functioning with other types of gas the nozzles must be replaced and
the primary air adjusted.
To replace the nozzles and regulate the burners, you have to remove the
top as described in the following paragraph.
5.1 Removing the hob
1. Remove all the knobs, the grids, the burner caps and the flame-caps;
2. remove the screws and the nuts A that secure the burner supports;
3. remove plates B;
4. lift the hob from its seat;
5. replace the burner nozzles in accordance with the reference gas
chart;
6. regulate the primary air as described in paragraph “5.2 Adjustment
for ULPG”.
5.2 Adjustment for ULPG
Loosen screw A and push support B all the way. Use a double head
wrench to remove nozzle C and assemble the suitable one, following the
instructions indicated in the reference charts, with respect to the type of
gas to use. The screwing torque of the nozzle should never exceed
3 Nm. Reposition support B so that nozzle C is covered perfectly.
Place the burner on its support and ignite it. Move the Venturi tube D to
regulate the air flow until the flame is stable and burns regularly, then
secure the tube by means of screw A.