Loading ...
Loading ...
Loading ...
INTRODUCTION
SAFETY REMINDERS
Adequate ventilation must be
provided in the room where the
tumble dryer is located to prevent
gases from appliances burning
other fuels, including open fires,
being drawn into the room during
operation of the tumble dryer.
Installing the rear of the appliance
close to a wall or vertical surface.
There should be a gap of at least
12 mm between the machine and
any obstrubtions. The inlet and
outlet should be kept clear of
obstruction. To ensure adequate
ventilation the space between the
bottomof the machine and the floor
must not be obstructed.
Exhaust air must not be
discharged into a flue which is used
for exhausting fumes from
appliances burning gas or other
fuels.
Check regularly that the air
flowing through the dryer is not
restricted.
Check frequently the fluff filter
after use, and clean, if necessary.
Check the fluff filter after use, and
clean, if necessary.
Prevent items from falling or
collecting behind the dryer as these
may obstruct the air inlet and outlet.
NEVER install the dryer up
against curtains.
VENTILATION
Important: During transport ensure that the dryer
is in an upright position, if it's necessary you can
only flip in the side shown;
Caution: If the product is in different side, wait at
least 4 hours before switching on so that the oil can
flow back into the compressor. Failure to do this
could result in damage to the compressor.
In cases where the dryer is
installed on top of a washing
machine, a suitable stacking kit
must be used, according to the
follow configuration.
Stacking kit Mod 35100019: for
minimum washing machine depth
= 49 cm
Stacking kit Mod 35900120:for
minimum washing machine depth
= 51 cm
The stacking kit shall be one of
that above, obtainable from our
spare service. The instructions for
installation and any fixing
attachments, are provided with the
staking kit.
EN 34
SALIDAS DE AIRE
SALIDAS DE AIRE EN LA BASE
TOMAS DE AIRE
Loading ...
Loading ...
Loading ...