Part Number 000015236 Rev 00 11/17 25
Checklist
If a problem arises during operation of your ice machine, follow the checklist below before calling service. Routine adjustments
and maintenance procedures are not covered by the warranty.
Problem Possible Cause To Correct
Ice machine does not operate.
No electrical power to the ice machine and/or
condensing unit.
Replace the fuse/reset the breaker/turn on
the main switch.
High pressure cutout tripping. Clean condenser coil. (See Section 4)
Power switch set improperly. Move the switch to the ON position.
Bin thermostat open or ice touching
thermostat probe.
Adjust thermostat or remove ice.
No water in reservoir.
No water to ice machine, plugged filter, float
valve defective.
Ice chute switch open. Check for ice or binding and close switch.
Low air temperature around ice machine. Air temperature must be at least 35°F (2°C).
Gearmotor runs and no ice is produced
Time delay has not expired. Wait 10 minutes for time delay to expire.
High pressure cutout tripping. Clean condenser coil and reset.
Low pressure control open. Thaw evaporator and retest - Call for service.
Low Production
Due for normal maintenance. Perform cleaning procedure. (See Section 4)
Ice machine starts and stops without a full bin
of ice.
Perform cleaning procedure. (See Section 4)