EN-11
● OPERATING INSTRUCTIONS ●
Even if these items are checked, when the unit does not recover from the
trouble, stop using the air conditioner and consult your dealer.
Symptom Explanation & Check points
Indoor Unit
The unit cannot be operated.
Is the breaker turned on?
Is the ON timer set? Page7
The unit cannot be operated
for about 3 minutes when
restarted.
This protects the unit according to instruc-
tions from the microprocessor. Please wait.
Mist is discharged from the air
outlet of the indoor unit.
The cool air from the unit rapidly cools mois-
ture in the air inside the room, and it turns
into mist.
The swing operation of the
HORIZONTAL VANE is
suspended for a while, then
restarted.
This is for the swing operation of the HORI-
ZONTAL VANE to be performed normally.
The air fl ow direction changes
during operation.
The direction of the horizontal
vane cannot be adjusted with
the remote controller.
In the heating operation, if the air fl ow tem-
perature is too low or when defrosting is be-
ing done, the horizontal vane is automatically
set to horizontal position.
The operation is stopped for
about 10 minutes in the heat-
ing operation.
Defrosting of the outdoor unit is being done.
Since this is completed in max.10 minutes,
please wait. (When the outside temperature
is too low and humidity is too high, frost is
formed.)
The unit starts operation by
itself when the main power
is turned on, though it isn’t
operated with the remote
controller.
These models are equipped with an auto re-
start function. When the main power is turned
off without stopping the unit with the remote
controller and is turned on again, the unit
starts operation automatically in the same
mode as the one set with the remote control-
ler just before the shutoff of the main power.
Refer to “Auto restart function”. Page 5
The indoor unit which is not
operating becomes warm and
a sound, similar to water fl ow-
ing, is heard from the unit.
A small amount of refrigerant continues to
ow into the indoor unit even though it is not
operating.
The indoor unit discolors over
time.
Although plastic turns yellow due to the infl u-
ence of some factors such as ultraviolet light
and temperature, this has no effect on the
product functions.
Outdoor Unit (Multi system)
When heating operation is
selected, operation does not
start right away.
When operation is started during defrosting
of outdoor unit is done, it takes a few minutes
(max. 10 minutes) to blow out warm air.
The fan of the outdoor unit
does not rotate even though
the compressor is running.
Even if the fan starts to rotate,
it stops soon.
When the outside temperature is low during
cooling operation, the fan operates intermit-
tently to maintain suffi cient cooling capacity.
Water leaks from the outdoor
unit.
During COOL and DRY operations, pipe or
pipe connecting sections are cooled and this
causes water to condense.
In the heating operation, water condensed
on the heat exchanger drips down.
In the heating operation, the defrosting op-
eration makes water frozen on the outdoor
unit melt and drip down.
White smoke is discharged
from the outdoor unit.
In the heating operation, vapor generated
by the defrosting operation looks like white
smoke.
Remote controller
The display on the remote
controller does not appear or
it is dim. The indoor unit does
not respond to the remote
control signal.
Are the batteries exhausted? Page 3
Is the polarity (+, -) of the batteries correct?
Page 3
Are any buttons on the remote controller of
other electric appliances being pressed?
Does not cool or heat
The room cannot be cooled or
heated suffi ciently.
Is the temperature setting appropriate?
Page 5
Is the fan setting appropriate? Please
change fan speed to Med. or High.
Is the fi lter clean? Page 9, 10
Is the fan or heat exchanger of the indoor
unit clean? Page 9, 10
Are there any obstacles blocking the air inlet
or outlet of the indoor or outdoor unit?
Is a window or door open?
It may take a certain time to reach the setting
temperature or may not reach that depend-
ing on the size of the room, the ambient
temperature, and the like.
Symptom Explanation & Check points
Does not cool or heat
The room cannot be cooled
suffi ciently.
When a ventilation fan or a gas cooker is
used in a room, the cooling load increases,
resulting in an insuffi cient cooling effect.
When the outside temperature is high, the
cooling effect may not be suffi cient.
The room cannot be heated
suffi ciently.
When the outside temperature is low, the
heating effect may not be suffi cient.
Air does not blow out soon in
the heating operation.
Please wait as the unit is preparing to blow
out warm air.
Airfl ow
The air from the indoor unit
smells strange.
Is the fi lter clean? Page 9, 10
Is the fan or heat exchanger of the indoor unit
clean? Page 9, 10
The unit may suck in an odor adhering to the
wall, carpet, furniture, cloth, etc. and blow it
out with the air.
Sound
Cracking sound is heard. This sound is generated by the expansion/
contraction of the intake grille, etc. due to
change in temperature.
The sound as burbling is
heard.
This sound is heard when the outside air is
absorbed from the drain hose by turning on
the range hood or the ventilation fan, making
water fl owing in the drain hose to spout out.
This sound is also heard when the outside air
blows into the drain hose in case the outside
wind is strong.
Burbling sound is heard from
the indoor unit when DRY/
COOL operation is stopped.
This is the sound of drained water owing
backward in the drain piping in the ceiling.
Mechanical sound is heard
from the indoor unit.
This is the switching sound in turning on/off
the fan or the compressor.
The sound of water fl owing
is heard.
This is the sound of refrigerant or condensed
water fl owing in the unit.
Hissing sound is sometimes
heard.
This is the sound when the ow of refrigerant
inside the unit is switched.
The sound of motor and
swirling sound is heard from
the indoor unit.
This is the sound of water condensed during
COOL/DRY operation being drained from the
indoor unit.
Sound of water draining may also be heard
from indoor units which are not operating.
(The sound will stop automatically. Please
wait.)
Timer
Weekly timer does not oper-
ate according to settings.
Is the ON/OFF timer set? Page 7
Transmit the setting information of the weekly
timer to the indoor unit again. When the infor-
mation is successfully received, a long beep
will sound from the indoor unit. If information
fails to be received, 3 short beeps will be
heard. Ensure information is successfully
received. Page 8
When a power failure occurs and the main
power turns off, the indoor unit built-in clock
will be incorrect. As a result, the weekly timer
may not work normally.
Be sure to place the remote controller where
the signal can be received by the indoor unit.
Page 4
The unit starts/stops the
operation by itself.
Is the weekly timer set? Page 8
Dirt
The ceiling and wall around
the indoor unit get dirty.
Please clean the periphery of the air condi-
tioner frequently.
It may prevent the dirt to lower the wind blow-
ing to the ceiling by adjusting the vertical wind
direction.
In the following cases, stop using the air conditioner and consult your
dealer.
When water leaks or drips from the indoor unit.
When the upper operation indicator lamp blinks.
When the breaker trips frequently.
The remote control signal is not received in a room where an electronic ON/
OFF type fl uorescent lamp (inverter-type fl uorescent lamp, etc.) is used.
Operation of the air conditioner interferes with radio or TV reception. An ampli-
er may be required for the affected device.
When an abnormal sound is heard.
When any refrigerant leakage is found.
WHEN YOU THINK THAT TROUBLE HAS OCCURRED
RG79Y943H01_en-1st.indd 11 2018/01/25 8:36:07