Loading ...
Loading ...
Loading ...
Page 7
ENGLISH
SAFETY INFORMATION
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current
Detection and Interruption) power cord that is required by UL. This
power supply cord contains state-of-the-art electronics that sense
leakage current. If the cord is damaged and leakage occurs, power will
be disconnected from the unit.
The test and reset buttons on the LCDI Plug are used to check if the
plug is functioning properly.
WARNING: Test LCDI before each use.
To test the plug:
1. Plug power cord into a grounded 3 prong outlet.
2. Press RESET (on some units a green light will turn on).
3. Press the TEST button, the circuit should trip and cut all power to the air
conditioner(on some units green light may turn off).
4. Press the RESET button for use. You will hear a click and the A/C is ready for use.
5. The power supply cord must be replaced if it fails to trip when the TEST button is
pressed and the unit fails to reset.
NOTES:
• The RESET button must be engaged for proper use.
Do not use the power supply cord as an ON/OFF switch. The power
supply cord is designed as a protective device.
CAUTION: A damaged power supply cord must be replaced with a new
power supply cord.
The power supply cord contains new user serviceable parts. Opening the tamper-
resistant case voids all warranty and performance claims.
NOTE: Your units power cord and plug may differ from the one shown.
WARNING – RISK OF FIRE
It is important the plug ts tightly into the wall outlet.
If the plug does not t securely and appears loose, it should not be used.
Have a licensed electrician replace the receptacle.
Loading ...
Loading ...
Loading ...