49
TYPICAL 6100 SERIES, 230/208-VOLT
WIRING DIAGRAM
TION BOARD UNIT
HEATER
CONNECTOR
CN102(WH)
CN103(BL)
CN112
BCN202
CN201(YL
)
CN105(BK
)
CT101
CN104
BCN106
BCN101.BCN108.BCN109
CN4.CN5.CN6
YL
YL
OR
OR
BK
BK
BL
BL
ROOM
I.D.
COIL
O.D.
CO
IL
OUTDOOR
BK
BR
GY
RD
GR
WH
BL
OR
BCN7.BCN9
BCN301.BCN302
OR
BL
WH
GR
RD
GY
BR
BK
RD
WH
TERMINAL
BOARD
RUNNING
CAPACITOR
HEATER(1.0kW)
HEA
TER(1.4kW)
HEA
TER(2.4kW)
BK
BR
RD
YL
WH
BL
FUSE
PROTEC
TOR
BR
YL
BL
DRIVE BOARD UNIT
3
3
CN1
1
2
3
4
5
8
FM
O.D.FAN MOTOR
BK
WH
YL
BL
RD
OR
RD
BL
YL
WH
BK
I.D.FAN MOTOR
FM
4
3
2
1
6
GR
*2
BR
*4
1
2
1
ICR
YL
YL
*4
RD
RD
RV
1
CN8
NR101
VARISTOR
RY102
RY110
RY101
T1
C
D
E
1
4
CN110
5
2
1
7
WH
WH
BK
BK
TRANSFORMER
*2
CN11
*2
1
2
3
4
56
7
8
1
2
3
6
5
4
8
9
9
7
6
5
4
3
2
1
*3
(265V)
(208/230V)
BCN112
BT1
BT2
YL
MAIN BOARD UNIT
OPEA
*1
*3
YL
OR BR
BK
O.L.P
BK
C
R
S
RD
WH
BL
COMP.
1
2
3
4
5
6
6
5
4
3
2
1
RD
BL
BK
BL
TRIAC UNIT
*1
1
2
3
3
2
1
BR
YL
BL
(1)CN103:PIN 1-2(BK-WH) DC15V; PIN1-6(BK-RD):
The DC voltage is AC power supply voltage x 1.4
(2)CN102:PIN1-2(BK-WH) DC15V; PIN1-5(BK-RD):
The DC voltage is AC power supply voltage x 1.4
Tu
wer supply for 2 minutes before
disconnecting motor connector (CN102.CN103).
or motor damage may occur.
5. This diagram applied to AZ61H series.
6. Heater resistance:
TEST TEMPERATURE IS 68degF.
195 ` 35%
200 ` 35%
200 ` 35%
205 ` 35%
75 ` 35%
85 ` 35%
CHECK POINT
HEATER
CONNECTOR
PIN NO.1-4
BK-BR
PIN NO.2-5
RD-YL
PIN NO.3-6
WH-BL
HEATER
HEATER RESISTANCE(ohm)
208V/230V
265V
1.0kW
1.4kW
2.4kW
TOR VOLTAGE:
NOTICE:
208/230V
PA052JB
265V
PA053JB
PRIMARY COIL
RESISTANCE(ohm)
BK-BK
SECONDARY COIL
RESISTANCE(ohm)
WH-WH
100 ` 10%
127 ` 10%
1.31 ` 10%
1.27 ` 10%
MODEL
NAME
4. TRANSFORMER WINDING RESISTANCE:
*1:The lead wires are multicolured with black tube.
*2:The jointwires are white ex
*3:The 7k BTU models don't have this wire.
*4:AZ61H series don't have these wires,except for
AZ61H07DAD.AZ61H09DAD.AZ61H12DAD.AZ61H15DAD.
AZ61H07EAD.AZ61H09EAD.AZ61H12EAD.AZ61H15EAD.
BK:BLACK
BL:BLUE
BR:BROWN
GR:GREEN
GY:GRAY
OR:ORANGE
RE:RED
WH:WHITE
YL:YELLOW
NOTE:
1.
2. COLOR:
3. THERMISTOR SENSOR RESISTANCE:
O.D COIL
&OUTDOOR
SENSOR RESISTANCE(ohm)
degF
10
30
32
50
70
90
ROOM I.D COIL
63260
34620
32860
19970
11950
7320
94900
51940
49330
29960
17930
10970
28030
15340
14570
8850
5300
3280
Loading ...
Loading ...
Loading ...