INSTALLATION INSTRUCTIONS
CONTINUED
Through your wall
Further to your various ducting options, below are some tips on how to
correctly duct your rangehood:
Always use correctly sized ducting – DO NOT reduce the size of the ducting
Always use solid ducting
Always use non-flammable ducting
Always duct to the outside atmosphere
Do not use flexible ducting
Do not duct into the ceiling space- always vent to the outside atmosphere.
Avoid sharp 90 degree bends as much as possible, use 45 degree bends
instead wherever possible
Duct to the outside atmosphere using the shortest duct run possible
Use cylindrical ducting whenever possible
Positioning the rangehood
Installation heights
Over gas and electric cookers, Residentia Group recommends our
rangehoods to be mounted at a height of between 600-800mm above the
cooking surface.
Electric cooktops must have a minimum height of 600mm from the
underside of the rangehood to the cooktop face.
Gas cooktops must have a minimum of 650mm from the burner to the
underside of the rangedhood.
Over open flame grillers or barbecues, the Gas Regulations require the
filters of the rangehood to be at least 1200mm above the cooking surface.
Installing the rangehood
Drill 4 x 8mm holes to accommodate the bracket. Screw and tighten the
bracket onto the wall with the screws and wall plugs provided.
Screw plug
Screw
(4mm x 30mm)
Wall bracket
Lift up the cooker hood and hang onto the wall bracket.
Cooker hood
Wall bracket