Operating the appliance
Note: Switch on the extractor hood when you start cooking and
switch it off again several minutes after you have finished
cooking. This is the most effective way of removing the kitchen
fumes.
Remote control
Connecting the remote control to the appliance
If the appliance cannot be operated with the remote control,
e.g. after the battery has been changed, the connection
between the remote control and the appliance must be re-
established.
1. Press and hold the @ button.
2. Attach the appliance to the mains voltage.
A long audible signal sounds. The remote control has been
connected to the appliance.
Note: If no audible signal sounds within 30 seconds, repeat
this procedure.
Setting the fan
Switching on
1. Press the @ button.
The fan starts at fan setting 2.
2. Press the @ or A button to set a different fan setting.
Note: The appliance has three fan settings and an intensive
setting. To set the lowest setting, press
A once. If you press it
more frequently, the appliance will switch off again.
Switching off
Press the
A button until the appliance switches off.
or press the
H button.
Intensive setting
You can use the intensive setting if there is a large build-up of
odours and fumes/vapours.
Press the
@ button until you hear the appliance switch into
intensive mode.
Note: The run time of the intensive mode is 4 minutes. Once
this time has elapsed, the appliance switches back to fan level
2.
Interval ventilation
With interval ventilation, the ventilation system switches on
automatically at level 2 for 10 minutes every hour.
1. Switch off the fan and the lighting.
2. Press and hold the H button until the light alternates
between being on and off.
The intermittent ventilation is activated and switches on after a
few seconds.
Note: You can switch off the interval function by pressing
the
@, A, H or y button.
Fan run-on
With fan run-on, the appliance switches off automatically after
10 minutes.
Press the
y button.
Note: The fan run-on is only activatable in fan levels 1-3.
Lighting
The lighting can be switched on and off independently of the
ventilation system.
Press the
B button.
Setting the brightness
Press and hold the
B button until the desired brightness is
reached.
Saturation signal
If the filters are saturated, an audible signal sounds:
Three consecutive audible signals: Clean the metal grease
filters
Six consecutive audible signals: Replace the activated
charcoal filters
See the Cleaning and maintenance section or the "CleanAir air
recirculation module" printed supplement.
Resetting the saturation signal
Press the
y button.
An audible signal sounds for three seconds.
Note: The appliance switches off the saturation signal
automatically after 20 hours.
Switching over the appliance to air recirculation
1. Switch off the appliance.
2. Press and hold the y button for four seconds until an audible
signal sounds.
The electronic control is switched over to air recirculation.
Switching over the appliance to air extraction
1. Switch off the appliance.
2. Press and hold the y button for four seconds until two
audible signals sound.
The electronic control is switched over to air extraction.
Explanation
B
Light on/off/dimming
@
Increase fan setting
A
Reduce fan setting
H
Interval ventilation
y
Fan run-on