About the controls on the air conditioner
Vent Control
The vent control is located behind the front grille on the right
side of the air discharge area. When CLOSED, only the air
inside the room will be circulated and conditioned. When
OPEN, the vent allows outdoor fresh air exchange.
To open or close the vent:
1. Remove the front grille.
2. Remove the vent card screw.
3. Remove vent card, turn it over and replace it by locating
rear hole in card over locating pin inside air discharge and
reattaching screw at front.
Horizontal louvers
on the front grille let you
control the air direction
up and down.
Remove the front grille to adjust
the vertical louvers side-to-side
to direct the air left
or right.
Air Direction
Locating hole
Screw hole
OPEN position
(Mesh end toward back)
CLOSE position
(Mesh end toward front)
Locating hole
Screw hole
The unit leaves the factory set at the CLOSE position.
No function (reserved
for future use)
Auxiliary Controls – Dip Switches (location varies by model)
The auxiliary dip switch controls are
ORFDWHGEHKLQGWKHURRPFDELQHW³DV
shown in this figure.
The owner is responsible for checking
switches and ensuring they are in the
desired position.
Fan Cycle/Continuous - Cool
Fan Cycle/
Continuous - Heat
Class 2
ON
ON
OFF
ON
ON
COOL
FAN
HIGH
MED
OFF
OFF
SLEEP
MODE
TIMER TEMP
+
-
Filter Reminder
Function
Auxiliary Controls – Dip Switches (location varies by model)
The auxiliary dip switch controls are located
EHKLQGWKHURRPFDELQHW³DVVKRZQLQWKLVILJXUH
The owner is responsible for checking switches
and ensuring they are in the desired position.
Fan Cycle/Continuous - Cool
Fan Cycle/Continuous - Cool
Filter Reminder Funtion
When this switch is enabled (RIGHT), it allows the indoor
fan to cycle on/off with the compressor. When this
switch is disabled (LEFT), it allows the indoor fan to run
continuously. The default setting is right (fan cycle).
When this switch is enabled (RIGHT), an LED will light
up the user interface after 250 of accumulated fan run
time. It serves as a reminder to clean the filter. When
this switch is disabled (LEFT), the function is disabled.
The default setting is right (enabled).
ON
ON
Fan Cycle/Continuous - Cool
Filter Reminder Function
Cool Only Models
Heat/Cool Models
8