G. If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similarly qualified
person in order to avoid a hazard.
9
(8) TROUBLESHOOTING
Fault
Cause
Solution
Light on, but motor
does not work
The fan is blocked
Remove the source
of the blockage
The capacitor damaged
Replace capacitor
The motor jammed and
bearing damaged
Replace motor
A smell coming from the
motor
Replace motor
Light does not
work, motor does
not work
Beside the above mentioned, check the following:
Light damaged
Replace lights
Power cord loose
Take to authorised
service centre.
Oil leakage
One way valve and the air
ventilation entrance are
not tightly sealed
Take down the one
way valve and seal
with silicon rubber.
Leakage from the
connection of U-shaped
section and cover
Take U-shaped section
down and seal with
silicon or paint
Shake of the body
The fan is damaged and
causes shaking
Replace the fan
The motor is not tightly
mounted
Lock the motor mounts
tightly
The body is not tightly
hung on wall
Fix the body tightly
Insufficient suction
The distance between the
body and the gas top too
long
Readjust the distance
Too much ventilation or
breeze from open doors or
windows
Choose a better
location and re-
assemble the machine
The machine
inclines
The fixing screw not tight
enough
Tighten the hanging
screw and make it
horizontal