SINGLE WALL OVENS
JJW2427I – 27" x 29-7/8" x 25-5/16"
JJW2430I, JJW3430I – 30" x 29-7/8" x 25-5/16"
ELECTRICAL REQUIREMENTS
If codes permit and a separate ground wire is used, it is recommended
that a qualified electrical installer determine that the ground path and
the wire gauge are in accordance with local codes.
Check with a qualified electrical installer if you are not sure the oven
is properly grounded.
This oven must be connected to a grounded metal, permanent
wiring system.
Be sure that the electrical connection and wire size are adequate and
in conformance with the National Electrical Code, ANSI/NFPA 70-latest
edition or CSA Standards C22.1-94, Canadian Electrical Code, Part 1
and C22.2 No. O-M91-latest edition, and all local codes
and ordinances.
A copy of the above code standards can be obtained from:
National Fire Protection Association
1 Batterymarch Park
Quincy, MA 02169-7471
CSA International
8501 East Pleasant Valley Road
Cleveland, OH 44131-5575
ELECTRICAL CONNECTION
To properly install your oven, you must determine the type of electrical
connection you will be using and follow the instructions provided for
it here.
Oven must be connected to the proper electrical voltage and
frequency as specified on the model/serial/rating plate. The
model/serial/rating plate is located under the control panel on
single ovens. See the following illustration
A. Model/Serial/Rating Plate
Models rated from 7.3 to 9.6 kW at 240 V (5.4 to 7.4 kW at 208
V) require a separate 40 A circuit. Models rated at 4.8 kW and
below at 240 V (3.6 kW and below at 208 V) require a separate
20 A circuit.
A circuit breaker is recommended.
Connect directly to the circuit breaker box (or fused disconnect)
through flexible, armored, or nonmetallic sheathed, copper cable
(with grounding wire).
Flexible conduit from the oven should be connected directly to
the junction box.
Fuse both sides of the line.
Do not cut the conduit. The length of conduit provided
is for serviceability of the oven.
A UL listed or CSA approved conduit connector
must be provided.
If the house has aluminum wiring, follow the procedure below:
Connect the aluminum wiring using special connectors and/or
tools designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer’s recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
For power requirements for models JJW2427I, JJW2430I and
JJW3430I, refer to the following table.
240 VAC 208 VAC
Model kW kW
JJW2427I
4.1 3.1
JJW2430I
4.1 3.1
JJW3430I
4.5 3.4
A