Ceiling/Shelf drilling and Plate Fixing
CEILING/SHELF DRILLING
Use a plumb-line and mark the centre of the cooking hob on the Support Ceiling/Shelf.
Rest the plate against the ceiling/shelf, taking care to keep the limit pawl that has just been
fitted in a position facing the installer and the cooking hob (the limit pawl must not be con-
fused with the other 4 used to fix the steel cables that move the Hood).
Mark on the ceiling the centres of the holes in the plate.
Drill the following points:
• Ceilings in solid concrete: As per concrete plugs used.
Ceilings in hollow bricks with 20 mm resistance thickness: Drill a hole ø 10 mm (insert
Plugs 11 supplied immediately).
• Ceilings with Wood Beams: As per Wood Screws used (not supplied).
• Wooden shelf, with a resistant thickness of 15 mm: drill a hole ø 7 mm.
Feeding the electric supply cable: drill a hole ø 10 mm.
Warning: there will be two lines to be connected: a direct electric line for the hood power
supply and another line with a switch for the lamp. This does not apply to Zoom model.
• Air Outlet (Ducting Version): according to the diameter of the connection to the external
ducting pipe.