9.Connect gas supplies to dryers.
Use pipe-joint compound resistant to
the action of L.P. gas for gas
connections. If flexible metal tubing is
used, be certain there are no kinks.
Note: Dryer door must be closed for
dryer to operate. When door is open,
dryer stops, but timer continues to run.
To restart dryer, close door and push
START/RESTART button.
8.Remove red caps from gas
pipes. Carefully move dryer into final
position. Place level on top of the
dryers or collar, first side to side; then
front to back. If the dryers are not
level, adjust the legs up or down until
level.
13.Carefully move dryer into
final position. Place level on top of
the dryer, first side to side; then front
to back. If the dryer is not level, adjust
the legs of the dryer up or down until
the dryer is level.
14.Plug power supply cord into
grounded outlet.
15.Check dryer operation (some
accumulated time may be on the
timer due to factory testing).
Insert coins in slide and press slide in
slowly. Push START/RESTART button.
Using a full heat cycle (not the air
cycle), let the dryer run for at least
five minutes. Dryer will stop when time
is used up.
11.Use a non-corrosive leak
detection fluid to check for leaks.
Bubbles around connections will
indicate a leak. If a leak appears,
shut off gas valve controls and adjust
connections. Then check
connections again. All connections
must be wrench-tightened.
Now Start...
Page 6
16.If the burner does not ignite
and you can feel no heat inside the
dryer, shut off dryer for five minutes.
Check that all supply valve controls
are in "ON" position and that the
electrical cord is plugged in. Repeat
five-minute test.
17.If drying time is too long,
make sure lint screen is clean.
With dryer in laundry area.
10.Open the shutoff valve in the
gas supply line.
Excessive Weight Hazard
Use two or more people to move
and install dryer.
Failure to do so can result in
back or other injury.
WARNING
1. Put on safety glasses and gloves.
Check that each leg is approximately
1 inch (2.5 cm) from base.
2. Wipe the interior of the drums
thoroughly with a damp cloth.
3. Install coin vaults and locks (not
supplied) into meter case openings.
4. Install control panel lock and
key (not supplied).
6. Secure coin slide mechanism
from inside the control panel using
the 3/16" bolt and washer included
with the slide mechanism. Install coin
box.
7. Repeat Steps 5 and 6 for the
other coin slide mechanism. Close
control panel.
5. Open control panel. Insert the
coin-slide mechanism through the
opening to left of the control panel.
12.To exhaust dryer, see
“Exhaust requirements,” Pages 3-4.
Connect exhaust vent system to dryer
exhaust outlet and exhaust hood
using 4" (10.2 cm) clamps. Use
caulking to seal exterior wall opening
around exhaust hood.