User manual Air Conditioner
-282086.png)
To ensure optimal efficiency of the product, keep doors and windows closed when it is used as an air conditioner or dehumidifier.
If the product is being used with the fan function only, an open window could improve air circulation.
-561273.png)
Important : Before installing the unit, place it UPRIGHT for 20 minutes before use to allow the refrigerant to stabilize.
WARNING
-687156.png)
1. Control Panel (Incl. Signal Receptor)
2. Air Outlet
3. Handle
4. Casters
5. Upper Drain Plug
6. Air Filter
7. Back Grill
8. Lower Drain Plug
9. Power Supply Cord
10. Exhaust Hose Connector
11. Remote Control
-316745.png)
1. Window Bracket Kit.............................1 Set
2. Window Bracket Panel Adapter..........1 Piece
3. Plastic Pin...........................................2 Pieces
4. Hose Connector..................................1 Piece
5. Plastic Hose........................................1 Piece
1. Install the plastic hose with window bracket adapter and hose connector on both sides. Ensure proper fit on both ends.
-611569.png)
2. Adjust the window bracket as per width or height of your window and insert the plastic pins to fix at the desired position.
-602179.png)
Note : Do not install the window bracket to your window. This step is required only to adjust it to the size of your window. The bracket should be removed from the window after the size is adjusted.
3. Connect the plastic hose to the hose connector on back of the unit. Push-in then rotate clockwise.
-915584.png)
4. Connect the window bracket to the opposite end of the plastic hose. Ensure that all connections are tight and installed properly.
-879059.png)
5. Connect the window bracket to the window.
-914272.png)
6. The Portable Air Conditioner is now ready to use.
Note:
-163555.png)
Warning:
-683864.png)
Power Control
The Power Control turns the unit on and off.
Mode Control
3 settings: Cool, Dehumidify and Fan
A light will indicate which setting is currently being used.
Cooling Mode -849478.png)
The unit works as an air conditioner. Adjust fan speed and air temperature to suit your desired comfort level. Temperature setting range is 61°F ~ 89°F
Dehumidifying Mode-607561.png)
Air is dehumidified as it passes through the unit, without being in full cooling mode. If room temperature is higher than 77°F fan speed can be adjusted; otherwise fan speed is preset "LOW".
Note : If the unit will be used mainly as a dehumidifier, do not connect the exhaust hose and let the warm air return in the room. Continuous drainage is then necessary and more efficient (refer page 14, Continuous Draining).
Fan Mode-562300.png)
For air circulation without cooling.
Fan Speed Control
3 settings: High, Medium and Low.
Timer Control
Auto turn off:
With machine in running mode, press timer button to select the number of hours you want the unit to run in air conditioning mode.
Auto turn on:
With machine in stand by mode, press the timer button to select the number of hours until you want the unit to automatically start running.
Temperature / Timer Set Controls
After 10 seconds the display will revert back to room temperature.
Temperature is only adjustable in cool mode.
The time is adjustable between 1~24 hours.
Note: By pressing both “ ▼ “ / “▲“ set buttons at the same time, the display will toggle between Celsius and Fahrenheit.
Warning Light
Condensed water may accumulate in the unit. If the internal tank becomes full, the Power Light will flash and the unit will not operate until the unit has been drained (refer page 14, Water Condensation Drainage).
After switching the air conditioner off, you must wait 3 minutes before switching it back on again.
The functions work the same as the portable air conditioner’s touch controls. All key functions can be accessed from the remote control.
-387435.png)
Note :
Battery Installation: Remove the cover on the back of the remote control and insert two AAA batteries with ‘‘+’’ and ‘‘-’’ pointing in the proper direction.
Caution-628057.png)
Appliance Maintenance:
Air Filter Maintenance:
The air filter should be cleaned every two weeks.
Clean it as follows:
Maintenance After Use:
When there is excess water condensation inside the unit, the air conditioner stops running and shows a warning light (refer to page 10). This warning light indicates that the water condensation needs to be drained using the following procedures:
Manual Draining
-517569.png)
Water may need to be drained in high humidity areas
Continuous Draining
-507678.png)
While using the unit in dehumidifier mode, continuous drainage is recommended.
The following troubleshooting guide addresses the most common problems. If problems persist, call customer service. Unplug and disconnect the appliance from the power source before attempting to troubleshoot.
| Problem | Possible Cause | Solution |
| The air conditioning unit does not start |
• No electricity. • Batteries in the remote control need to be replaced. • The power cord is not properly plugged in. • The safety GFI plug has tripped. |
• Check for power. • Change remote control batteries. • Remove and reconnect the power cord. Reset the safety GFI plug, if problem persists contact our customer support. |
| Runs a short while only |
• The thermostat temperature setting is too close to room temperature. • Air outlet is blocked. • There are tight bends in the air exhaust hose. |
• Lower the set temperature. • Make sure the exhaust hose is properly connected. • Connect exhaust hose as per instructions on page 9. |
| Runs but no cooling |
• A door or window is open. • The air filter is dirty. • The exhaust hose is detached. • Temperature setting is too high. • Air outlet or intake is block |
• Make sure the window or door is closed • Clean the air filter • Reinstall exhaust hose properly (refer to page 9, Installation) • Reduce temperature setting on control panel. • Remove blockage. |
| Will not run and water full indicator light is ON | • Excess water condensation inside the tank. | • Drain the water. (refer to page 14, Water Condensation Drainage). |
Reference file: Honeywell MN10CESWW Rooms Up To 350-450 Sq. Ft Air Conditioner
Additionally, the document applies to other Honeywell models: MN12CES