BURNER NORMAL
POWER
kW
MINIMUM
POWER
kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30
mbar
G31 37 mbar
Semi-rapid 2,0 0,6 71 145 143
Auxiliary 1,0 0,33 50 73 71
Data in the table is specified
for Malta.
10. ENERGY EFFICIENCY
10.1 Product information according to EU 66/2014
Model identification KGS9536RN,
KGS9536RS,
KGS9536SX,
KGS9536T,
KGS9536W
Type of hob Built-in hob
Number of gas burners 5
Energy efficiency per gas burner
(EE gas burner)
Left front - Semi-rapid 55.3%
Left rear - Semi-rapid 57.4%
Middle - Multi Crown 54.3%
Right front - Rapid 58.5%
Right rear - Auxiliary not applicable
Energy efficiency for the gas hob
(EE gas hob)
56.4%
EN 30-2-1: Domestic cooking appliances burning gas - Part 2-1 : Rational use of
energy - General
10.2 Energy saving
Before use, make sure that the burners and pan supports are assembled correctly.
Use cookware with diameters applicable to the size of burners.
Center the pot on the burner.
When you heat up water, use only the amount you need.
If it is possible, always put the lids on the cookware.
When the liquid starts to boil, turn down the flame to barely simmer the liquid.
If it is possible, use a pressure cooker. Refer to its user manual.