Loading ...
Loading ...
Loading ...
Applicable types of cables for different
phases:
Phase Min. size cable
1 3x6.0 mm²
3 with neutral 5x1.5 mm²
WARNING! The power cable must
not touch the part of the appliance
shaded in the illustration.
COVERING TERMINAL BOARD
The recommended cross-section area is six
square millimetres (6 mm²).
When you refit the mains terminal cover, make
sure that the lower tabs are located inside the
bottom edge of the aperture, before you fix the
two screws into the top edge of the mains
terminal cover.
Make sure that the cover is securely fastened.
To open the cover of terminal board
obey the procedure in opposite
sequence.
TERMINAL BOARD
Do not remove blanking plates.
Make sure that the links are fitted as shown.
ENERGY EFFICIENCY
PRODUCT INFORMATION FOR HOB ACCORDING TO EU 66/2014
Model identification ZCI66250BA
ZCI66250WA
ZCI66250XA
Type of hob Hob inside Freestanding Cooker
Number of cooking zones 4
Heating technology Induction
Diameter of circular cooking
zones (Ø)
Left front
Left rear
Right front
Right rear
21.0 cm
14.0 cm
18.0 cm
18.0 cm
27
Loading ...
Loading ...
Loading ...