BATTERY CHARGING (SEALED BATTERY)
Always verify battery condition before and 1-2 hours after the end of charging.
STATE OF CHARGE VOLTAGE ACTION
CHARGE TIME
(USING CONSTANT
CURRENT
CHARGER @
STANDARD AMPS
SPECIFIED ON TOP
OF BATTERY)
100% 12.8-13.0 volts None, check at 3 mos.
from date of
manufacture
None required
75%-100% 12.5-12.8 volts May need slight
charge, if no charge
given, check in 3
months
3-6 hours
50%-75% 12.0-12.5 volts Needs charge 5-11 hours
25%-50% 11.5-12.0 volts Needs charge At least 13 hours,
verify state of charge
0%-25% 11.5 volts or less Needs charge with
desulfating charger
At least 20 hours
CAMBER AND CASTER
The camber and caster are non-adjustable.
REAR SPRING
The rear shock absorber spring is adjusted by rotating the adjuster either
clockwise or counter-clockwise to increase or decrease spring tension.
Accessory springs are available through your POLARIS dealer.