LG DLG2241W - 27 Inch 7.3 cu. ft. Gas Dryer

OWNER’S MANUAL - Page 16

For DLG2241W. Also, The document are for others LG Electronics models: DLE2140*, DLE2240*, DLG2141*, DLG2241*

PDF File Manual, 84 pages, Read Online | Download pdf file

DLG2241W photo
Loading ...
Loading ...
Loading ...
Routing and Connecting Ductwork
Follow the guidelines below to maximize drying
performance and reduce lint buildup and
condensation in the ductwork.
NOTE: Ductwork and fittings are NOT included
and must be purchased separately.
• Use4inches (10.2 cm) diameter rigid or
semirigid metal ductwork.
• Theexhaustductrunshouldbeasshortas
possible.
•Useasfewelbowjointsaspossible.
• Themaleendofeachsectionofexhaustduct
must point away from the dryer.
•Useducttapeonallductjoints.
• Insulateductworkthatrunsthroughunheated
areas in order to reduce condensation and lint
buildup on duct surfaces.
IMPORTANT: Failure to exhaust the dryer
correctly will void the dryer’s warranty.
VENTING THE DRYER (cont.)
Correct Venting
Incorrect Venting
NOTE: Deduct 6 ft. (1.8 m) for each additional elbow. It is not recommended to use more than four 90° elbows.
65 ft. (19.8 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
36 ft. (11.0 m)
28 ft. (8.5 m)
55 ft. (16.8 m)
47 ft. (13.7 m)
41 ft. (12.5 m)
30 ft. (9.1 m)
22 ft. (6.7 m)
Ductwork
4"
(10.2 cm)
4"
(10.2 cm)
Recommended
2
1
/2"
(6.35 cm)
Use Only for Short
Run Installations
Wall Cap Type
0
1
2
3
4
0
1
2
3
4
Number of 90° Elbows
Max. Length of 4 inches Dia.
Rigid Metal Duct