WARNING!
BEFORE INSTALLATION
This appliance shall only be installed by an
authorized professional.
This appliance shall be installed in accordance
with the manufacturer's installation instructions.
This appliance must be installed in accordance
with the standards of the country where it will
be installed. The installation of this appliance
must conform to local codes and ordinances. In
the absence of local codes, Installations must
conforms to American National Standards,
National Fuel Gas Code ANSI Z223.1 - latest
edition/NFPA 54 or B 149.1.
The appliance, when installed, must be
electrically grounded in accordance with local
codes or, in the absence of local codes, with the
National Electrical Code, ANSI/NFPA 70.
If local codes permit, a flexible metal appliance
connection with the new AGA or CGA certified
design, max. 5 feet (1,5 m) long, 3/4" I.D. is
recommended for connecting this appliance to
the gas supply line. Do not bend or damage the
flexible connector when moving the appliance.
This appliance must be used with the pressure
regulator provided. The regulator shall be
properly installed in order to be accessible when
the appliance is installed in its final location. The
pressure regulator must be set for the type of
gas to be used. The pressure regulator has 3/4"
female pipe thread. The appropriate fitting must
be determined based on the size of your gas
supply line, the flexible metal connector and the
shutoff valve.
The appliance must be isolated from the gas
supply piping system by closing its individual
manual shutoff valve during any pressure
testing of the gas supply piping system at test
pressures equal to or less than 34 PSI (13,8 w.c.
pr 3,5 kPa).
All opening and holes in the wall and floor, back
and under the appliance shall be sealed before
installation of the appliance.
A manual valve shall be installed in an
accessible location in the gas line external to
the appliance for the purpose of turning on or
shutting off gas to the appliance
Do not use aerosol sprays in the vicinity of
this appliance while it is in operation
ROOM VENTILATION: An exhaust fan may be
used with the appliance; in each case it shall be
installed in conformity with the appropriate
national and local standards. Exhaust hood
operation may affect other vented appliances; in
each case it shall be installed in conformity with
the appropriate national and local standards.
  
This appliance is shipped from the factory for
use with natural gas. Propane Conversion Kit
must be purchased separately. For use with
propane LP gas please follow the conversion
procedure described on pg. 17.
 
The maximum inlet gas supply pressure
incoming to the gas appliance pressure
regulator is 34 PSI (13,8 w.c. pr 3,5 kPa).
The minimum gas supply pressure for checking
the regulator setting shall be at least 1" w.c. (249
Pa) above the inlet specified manifold pressure
to the appliance (this operating pressure is 4"
w.c. (1.00 kPa) for Natural Gas and 11" w.c. (2.75
kPa for LP Gas).