GAS CONNECTION
This appliances is suitable for installation with Natural
Gas or ULPG
Refer to page 11 for the relevant burner pressure and
appropriate injector sizes. When the appliance is to be
connected to Natural Gas then the pressure regulator
supplied must be fitted to the gas inlet. A test point (for
checking the gas pressure) is supplied either with the
regulator or as a separate fitting in the case of ULPG
appliances.
Connection of the appliance to the gas supply must be
in accordance with the requirements of AS5601. A ½”
BSP connector at the inlet is recommended and the gas
supply line to the appliance must be of adequate length
to allow sufficient withdrawal of appliance for service or
disconnection and be:
a)
annealed copper pipe; or
b)
a hose assembly complying with the requirements of AS1869
-
Class
B, 1Omm diameter, maximum length 1OOOmm.
The appliance must be installed with provision to allow the gas to be turned off
and disconnected for servicing and removal of the appliance as required from
the gas supply.
Before the appliance is operated make certain all relevant parts are placed in
the correct position.
When the installation is completed the installation connections of appliance will require
to be leak tested, the burner operating pressure and flame checked and adjusted.
Warranty service calls do not cover these adjustments!
To check the operating pressure of the appliance it is recommended at last 2
large size burners are used. Ensure appliance is secured to wall when installation
is completed.
N.G. The regulator supplied must be fitted to the
½”
BSP thread at the rear of
the appliance. An approved manual shut-off valve must be installed. The N.G.
regulator must be checked and adjusted to 1.0kPa after installation.
ULPG
Can be connected to the inlet fitting directly. The
pressure must be checked to ensure it is operating at
2.75kPa. A separate test point fitting must be installed
between the piping & the appliance for the pressure to
be checked to ensure it is operating at 2.75kPa.