Loading ...
Loading ...
Loading ...
5
Instructions for user - 9120-15002 - MCX - 801052 - March 2013 v1.01
Type MCX 3 MCX 4 MCX 6
Part no. 27300 27400 27600
Capacity (Liter) 0,2 0,2 0,2
Nominal pressure MPa (bar) 1 (10) 1 (10) 1 (10)
Heating system
IES system
bare resistance element
Required water resistance at 15 °C
in cm
1100 800 800
Electric supply 1/N/PE ~ 220 V – 240 V
Nominal power rating 3,5 kW 4,4 kW 5,7 kW
Nominal current 15 A 19 A 25 A
Temperature choice 35 °C – 38 °C – 45 °C
Factory temperature setting 38 °C 38 °C 38 °C
Maximum inlet temperature 70 °C 70 °C 70 °C
Factory flow setting at 0.3MPa (3 bar) 2,0 l/min 2,5 l/min 3,3 l/min
Maximum temperature
increase at rated power
and a flow rate of......
1
2,0 l/min 25 K 31 K 41 K
2,5 l/min 20 K 25 K 33 K
3,0 l/min 17 K 21 K 27 K
3,5 l/min 14 K 18 K 23 K
4,0 l/min 12 K 16 K 20 K
Required l/min to switch on (l/min) 1,2 1,5 1,5
Required l/min to switch off
(l/min) 1,0 1,3 1,3
Min. required cable size
2)
See note 2)
Weight filled with water (kg) approx. 1,5
Dimensions H × W × D (mm) 135 × 186 × 87
Protection class acc. to VDE 1
Ingress protection according to VDE IP 25
1) Temperature rise (Kelvin) + cold-water temperature =
maximum hot-water temperature (°C) 70 °C
2) The cross sectional area of the connection cable must be in accordance with the power rating of the appliance and the specific require-
ments of AS/NZS 3000.
4. Technical specifications
Loading ...
Loading ...
Loading ...