GB7
MAINTENANCE
WARNING:
- Use protective gloves.
- Disconnect the appliance from the power supply
GREASE FILTERS
The metal grease lter has an unlimited life and should be cleaned once a month by hand or in a dishwasher at low temperature and
with a short cycle. Cleaning in a dishwasher may cause discolouring of the grease lter, but its ltering eciency is unaected.
Pull out the handle to remove the lter.
Wash the lter and leave it to dry, proceeding in reverse order to ret it.
REPLACING HALOGEN LAMPS
1. Disconnect the hood from the household power supply.
2. Use a small screwdriver to gently prise (near the three points indicated) the lamp cover o.
3. Remove the burnt-out lamp and t a new one.
Lamp
Power
(W)
Socket
Voltage
(V)
Dimension
(mm)
ILCOS D Code
(according IEC 61231)
10 G4 12
10 (Diameter)
22( Light Center
Length)
HSGST/C/UB-10-
12-G4-10/22
4. Ret (snap-on) the lamp cover.
ACTIVE CARBON FILTER (lter hoods only):
The carbon lter must be cleaned once a month in a dishwasher at the highest temperature, using a normal
dishwasher detergent. It is advisable to clean the lter separately.
After cleaning, reactivate the carbon lter by drying it in the oven at 100°C for 10 minutes.
Change the carbon lter every 3 years.
Fitting the carbon lter:
1. Remove the grease lter.
2. Hook the carbon lter rstly to the metal tab at the back on the hood and then x it at the front with the two
knobs.