GAS BURNERS FOR NATURAL GAS G20 20 mbar
BURNER NORMAL POWER kW MINIMUM POWER kW INJECTOR MARK
Rapid 3,0 0,75 119
Semi-rapid 2,0 0,45 96
Auxiliary 1,0 0,33 70
WARNING! This appliance does not
function with the existing gas settings
if installed in Malta. Therefore, before
connecting the appliance it is essential
to change the nozzles according to the
type of gas used according to the
table below.
GAS BURNERS FOR LPG G30/G31 28-30/37 mbar
BURNER
NORMAL
POWER kW
MINIMUM
POWER kW
INJECTOR
MARK
NOMINAL GAS FLOW g/h
G30 28-30 mbar G31 37 mbar
Rapid 2,8 0,75 86 204 200
Semi-rapid 2,0 0,45 71 145 143
Auxiliary 1,0 0,33 50 73 71
Data in the table is specified for Malta.
ENERGY EFFICIENCY
PRODUCT INFORMATION ACCORDING TO EU 66/2014
Model identification ZGH62414WA,
ZGH62414XA,
ZGH62414XS
Type of hob Built-in hob
Number of gas burners 4
Energy efficiency per gas burner
(EE gas burner)
Left rear - Semi-rapid 57.5%
Right rear - Semi-rapid 57.5%
Left front - Rapid 58.0%
Right front - Auxiliary not applicable