Loading ...
Loading ...
Loading ...
Installation
Gas adjustment
Before any adjustment is started the gas and electricity supply to the appliance
must be turned off.
Change the injector of the burners
Remove the pan support, burner cover and flame spreader
Unscrew the injector using a spanner and replace it with the stipulated injector
for the new gas supply.
Carefully reassemble all of the components.
After the injectors are replaced, you must ensure the replacement injectors
are fully tightened.
Adjustment of the minimum flame level
Turn the taps down to the minimum level
Remove the dial from the tap and place a small bladed screw driver in the brass
screw just to the right of the tap. Turn to adjust the flame level.
The correct adjustment is obtained when the flame has a length of 3mm - 4mm
(for butane/propane gas the adjustment screw must be tightly screwed in).
For Customer Services & Spare Parts please call 0345 208 8750
or visit us at https://mda.russellhobbs.com
13
Injector
Loading ...
Loading ...
Loading ...