Loading ...
Loading ...
Loading ...
En-11
AIR CONDITIONER Wall Mounted Type
OPERATING MANUAL
Care and Cleaning
Replacing the air cleaning fi lter
1. Open the intake grille and remove the air fi lters.
Please refer to the page 10.
2. Remove the dirty air cleaning fi lters attached to
the frames of the front panel.
Air cleaning fi lter frame
Air cleaning fi lters
3. Attach the new or maintained air cleaning fi lters to
the frame of the front panel.
Air cleaning fi lter frame
Air cleaning fi lter
Tabs (7 places)
Tabs (7 places)
The new air cleaning fi lters can be attached to the right frame or
the left frame.
Replace fi lters with the following components (purchased sepa-
rately).
● APPLE-CATECHIN FILTER: UTR-FA16
● ION DEODORIZATION FILTER: UTR-FA16-2
4. Install the air fi lters and close the intake grille.
Please refer to page 10.
Following 2 types of air cleaning fi lters are used in this product.
When you replace them, purchase dedicated air cleaning fi lters for this
product.
Apple-catechin fi lter: UTR-FA16
(1 sheet)
The Apple-catechin fi lter uses static electricity to clean fi ne particles
and dust in the air such as tobacco smoke and plant pollen that are
too small to see.
• This fi lter is disposable. Do not wash or reuse it.
• Once you open the package, use it as soon as possible. The
cleaning effect is reduced if the fi lter is left with the package opened.
• Replace the fi lter once every 3 months under normal use.
• By setting the fan speed high, the air cleaning effect increases.
Ion deodorization fi lter: UTR-FA16-2
(Light blue, 1 sheet)
The fi lter deodorizes by powerfully decomposing absorbed odors
using the oxidizing and reducing effects of ions generated by the
ultra-fi ne-particle ceramic.
• To maintain the deodorizing effect, clean the fi lter once every 3
months as follows:
1. Remove the fi lter.
2. Flush the fi lter with high-pressure hot water until the surface of
the fi lter is covered with water.
3. Wash the fi lter gently with diluent nuetral detergent. Do not wash
it by wringing or rubbing to prevent reducing the deodorizing
effect by damage.
4. Rinse the fi lter well with water fl ow.
5. Dry the fi lter throughly in a shaded place.
6. Reinstall the fi lter to the indoor unit.
• Replace the fi lter once every 3 years under normal use.
After extended non-use of the unit
If you have shut down the indoor unit for 1 month or more, perform the
FAN operation for half a day to dry the internal parts throughly before
you perform normal operation.
Additional inspection
After long period of use, accumulated dust inside the indoor unit may
reduce the product performance even if you have maintained the unit
with instructed daily care or cleaning procedures written in this manual.
In such a case, a product inspection is recommended.
For more information, consult authorized service personnel.
9319356082_01_OM_EN.indd 119319356082_01_OM_EN.indd 11 7/1/2013 11:02:53 AM7/1/2013 11:02:53 AM