LOCATION
It must be possible to disconnect the
appliance from the mains power
supply; the plug must therefore be
easily accessible after installation.
The appliance should be installed well away from
sources of heat such as radiators, boilers, direct
sunlight etc. Ensure that air can circulate freely
around the back of the cabinet. To ensure best
performance, if the appliance is positioned below
an overhanging wall unit, the minimum distance
between the top of the cabinet and the wall unit
must be at least 100 mm . Ideally, however, the
appliance should not be positioned below
overhanging wall units. Accurate levelling is
ensured by one or more adjustable feet at the base
of the cabinet.
100 mm
15 mm 15 mm
DOOR REVERSIBILITY
WARNING! Before carrying out any
operations, remove the plug from the
power socket.
CAUTION! To carry out the following
operations, we suggest that this be
made with another person that will
keep a firm hold on the doors of the
appliance during the operations.
1. Tilt back the appliance carefully so that the
compressor cannot touch the floor.
2. Unscrew both adjustable feet.
3. Unscrew the screws of the door bottom hinge.
4. Take off the appliance door by pulling it slightly
downwards.
5. Unscrew the top door hinge pin of the
appliance then screw it back on the other side.
2
1
6. Fit the appliance door on the upper door hinge
pin.
7. Remove the lower hinge. Put over the pin in the
direction of the arrow.
8. Unscrew and install the screw on the opposite
side.
9. Install the lower hinge on the opposite side
leaving the position of the door unchanged.
10. Screw in the one screw in the place set free on
the other side as well as the adjustable feet (2
pieces).
11. Remove and install the handle on the opposite
side.