Hints for test centres
Before starting any test it is necessary to fill completely with salt the salt container and with rinse aid the rinse
aid dispenser.
IST39en
Test standard EN 50242
Reference programme: Bio Wash
Load: 12 standard place settings
Rinse aid selector: position 5
Detergent dosage : 25 g in the dispenser
5 g on the dispenser lid
US50
UI50
Arrangement
upper basket
Arrangement
lower basket
UI65
Arrangement
cutlery basket
DIMENSIONS Width 60 cm
Height with worktop 85 cm
Height without worktop 82 cm
Max depth 61 cm
Max depth with open door 115.2 cm
ELECTRICAL CONNECTION Voltage 220-240 V - 50 Hz
MOTOR RATING DURING WASH 200 W
POWER OF HEATING ELEMENT 2100 W
OVERALL POWER 2300 W
WATER SUPPLY PRESSURE Minimum 50 kPa (0.5 bar)
Maximum 800 kPa (8 bar)
CAPACITY 12 place settings
Technical specifications