Hestan Aspire 12 inch Double Side Burner Built-In Grill 30000 BTU AEB122LPYW

Product's Documents

Below are documents related to this product, you can read online or download:
User Manual Specification
AEB122LPYW photo

User Manual.

This is the main product document for model AEB122LPYW.

The file format is pdf, 31 pages, you can download this manual here .

background
OUTDOOR COOKING
Outdoor Side Burner
AEB
Use & Care Manual
Installation & Operation
background
©2018 Hestan Commercial Corporation
1
EN
Message from Aspire by Hestan:
Outdoor cooking is a perfectionist’s pursuit, and with your new investment,
you’ve now taken the ultimate step forward. We sincerely welcome you to the
Aspire by Hestan Family. We’ve engineered and built our products so that
your guests will rave about your meal, but deep down, our customers know it
could’ve been just a little more tender, juicier – a pinch more salt in the rub or
a few seconds less on the ame. Yes, we’ve taken the time to know our Aspire
by Hestan customer and we’re excited to be on this journey with you. Aspire
by Hestan was born from this same perfectionist passion. Our engineers
experimented, innovated, tweaked and tinkered until they created the most
powerful, versatile and reliable outdoor products available.
We pride ourselves on restless innovation, superior engineering and purpose-
built designs, but also our in-depth understanding of our target consumer and
the interests and needs of the ultimate end-users we serve and covet. For many
consumers, cooking outdoors is much more than an act of food preparation. It’s
a lifestyle activity that encompasses culinary, leisure and social pursuits among
others.
We are thankful and proud that you have chosen Aspire by Hestan, and we
yearn to have you as a customer for life. We take your decision to choose Aspire
by Hestan most seriously, and we promise to deliver the very best to you.
Welcome to Aspire by Hestan
background
©2018 Hestan Commercial Corporation
2
EN
IF THE INFORMATION IN THIS MANUAL IS NOT FOLLOWED
EXACTLY, A FIRE OR EXPLOSION MAY RESULT CAUSING
PROPERTY DAMAGE, PERSONAL INJURY, OR DEATH.
Do not try lighting this appliance without reading the LIGHTING
INSTRUCTIONS section of this manual.
For outdoor use ONLY. This cooking appliance is not intended to be
installed in or on recreational vehicles, and/or boats.
Flammable Gas - disconnect all propane or natural gas supplies to this
unit before servicing.
Electrical Parts & Components – disconnect all power supplies and
batteries before servicing.
DANGER
If you smell gas:
1. Shut off gas to the appliance.
2. Extinguish any open flame.
3. Open lid.
4. If odor continues, keep away from the
appliance and immediately call your gas
supplier or your fire department.
DANGER
1. Do not store or use gasoline or
other flammable liquids or vapors
in the vicinity of this or any other
appliance.
2. An LP cylinder not connected for
use shall not be stored in the vicinity
of this or any other appliance.
READ THIS MANUAL CAREFULLY AND COMPLETELY BEFORE USING
YOUR SIDE BURNER TO REDUCE THE RISK OF FIRE, BURN HAZARD,
OR OTHER INJURY. KEEP THIS MANUAL FOR FUTURE REFERENCE.
background
©2018 Hestan Commercial Corporation
3
EN
3 MODEL NUMBERS
4 RATING LABELS
4 PRECAUTIONS
7 REGULATORY / CODE REQUIREMENTS
7 PORTABLE LP CYLINDERS
8 LOCATION AND ASSEMBLY
8 INSTALLATION
11 GAS AND ELECTRICAL CONNECTIONS
18 LIGHTING INSTRUCTIONS
19 USING YOUR SIDE BURNER
19 CLEANING AND MAINTENANCE
22 TROUBLESHOOTING
23 WIRING SCHEMATICS
27 PARTS LIST
27 SERVICE
27 WARRANTY
TABLE OF CONTENTS
BUILT-IN MODELS
Model No. Description
AEB121-NG / -LP 12” BUILT-IN SINGLE SIDE BURNER
AEB122-NG / -LP 12” BUILT-IN DOUBLE SIDE BURNER
AEB121
AEB122
MODEL NUMBERS
background
©2018 Hestan Commercial Corporation
4
EN
RATING LABEL
The rating label contains important information about your appliance such as the model and serial number,
gas type and manifold pressure, the BTU rating for each burner type, and the minimum installation
clearances.
PRECAUTIONS - BEFORE YOU USE YOUR SIDE BURNER
When properly cared for, your Aspire side burner will provide safe, reliable service for many years.
However, extreme care must be used since the side burner produces intense heat, which can cause serious
injury or even death if the instructions are not followed carefully. When using this appliance, basic safety
practices must be followed as outlined below.
1. NEVER LEAVE THE SIDE BURNER UNATTENDED WHILE COOKING.
2. Children should not be left alone or unattended in an area where the side burner is being used. Never
allow them to sit, stand, or play on or around the side burner. Do not store items of interest to children
around or below the side burner.
3. Never operate the side burner while under the influence of alcohol or drugs.
4. Never use the side burner in windy conditions. If located in a consistently windy area, oceanfront,
mountaintop, etc., a windbreak will be required. Always adhere to the specified clearances as described in
the INSTALLATION section of this manual.
5. The side burner shall be used only outdoors and shall not be used in buildings, garages, sheds, breezeways,
or any enclosed areas. Do not operate the side burner under unprotected, combustible construction. Use
only in well-ventilated areas. See the INSTALLATION section of this manual.
6. Do not use the side burner unless a leak check has been performed on all gas connections. See the GAS
CONNECTIONS section of this manual.
7. If the side burner is installed by a professional installer or technician, be sure that they show you where
your gas supply shut-off is located. All gas lines must have a shut-off that is easily accessible. If you smell
gas, check for leaks immediately. Check only with a soap and water solution. Never check gas leaks with
an open flame. See the GAS CONNECTIONS section of this manual.
8. Check the regulator, hoses, burner ports, and venturi / valve section carefully. Always turn off gas at the
source (tank or supply line) prior to inspecting parts.
9. When lighting a burner, always pay close attention to what you are doing. Be certain you are turning the
correct knob labeled for the burner you intend to use. If any burner does not light, or goes out during
operation, turn off all gas control knobs, and wait five (5) minutes before attempting to re-light. See the
LIGHTING INSTRUCTIONS section of this manual.
Outdoor Side Burner rating label is located on the inside rear wall of the unit, behind
the control panel.
background
©2018 Hestan Commercial Corporation
5
EN
10. Portable LP cylinders - Always shut off the main valve on the liquid propane (LP) cylinder after each use.
Never use a dented or rusted LP cylinder. Never attach or disconnect an LP cylinder, or move or alter gas
fittings when the side burner is in operation or is hot.
11. Inspect LP gas supply hose prior to each use of the side burner. The hose must be kept away from heated
areas of the side burner. If there is evidence of excessive abrasion or wear, or the hose is cut, it must be
replaced before using the side burner. The hose and LP regulator are supplied as a complete assembly
and must be replaced together. Do not attempt to repair or replace the hose itself. Contact your Hestan
dealer for genuine replacement P/N 014309.
12. Keep any electrical supply cord away from the heated areas of the side burner. The cord is provided with
a 3-prong grounding plug which should not be removed or altered. Do not use this appliance with an
ungrounded, 2-prong adapter. The cord must be plugged into a properly grounded GFCI-protected outlet.
See INSTALLATION section of this manual.
13. Spiders and insects like to nest in the burners, venturis, valves, and orifices of a side burner, disrupting the
gas flow in the burner. This very dangerous condition can cause a fire behind the control panel, damaging
the side burner and risking personal injury. If your side burner has been unused for a long time, inspect
and clean the burners, venturis, valves, and orifices. It is recommended you inspect your side burner at
least twice a year. See BURNER ADJUSTMENT section of this manual for details.
14. Keep the areas surrounding the side burner free from combustible materials, trash, or combustible fluids
and vapors such as gasoline or charcoal lighter fluid. Do not obstruct the flow of combustion gases and
ventilation airways (front).
15. Never move the side burner when hot. When in use, portions of the side burner are hot enough to cause
severe burns.
16. Always have an “ABC” type fire extinguisher accessible – never attempt to extinguish a grease fire with
water or other liquids.
17. Avoid wearing loose-fitting garments or long sleeves while cooking with the side burner. They could
ignite. For personal safety, wear proper apparel while cooking. Some synthetic fabrics are highly
flammable and should not be worn while cooking.
18. Never let pot holders, covers, or other flammable materials come in contact with or too close to any
cooking grate, burner, or hot surface until it has cooled down sufficiently. Fabrics may ignite and result
in personal injury. Use only dry potholders. Moist or damp potholders on hot surfaces may cause burns
from steam. Do not use a towel or bulky cloth in place of potholders. Do not let potholders touch hot
portions of the cooking grates.
19. Never touch the cooking grates or immediate surrounding metal surfaces with your bare hands while
cooking with the side burner, as these areas become extremely hot and could cause burns. Use only the
handles and knobs provided for operation of the side burner.
20. Protect your hands with an insulated glove or mitt when operating the side burner. Always keep your
face away and open lids slowly on pots and pans to allow heat and steam to escape before fully opening.
Never lean over an open hot side burner.
21. The side burner metal cover must be removed while lighting. Leaving the cover in place while lighting
can result in an explosion and personal injury, or death. Never lean over a side burner or look directly
into the burner when attempting to light. See the LIGHTING INSTRUCTIONS section of this manual.
22. Do not heat unopened food containers (cans) as pressure build-up will cause the container to explode.
23. Do not use aluminum foil to line the burner bowl. This will alter the airflow to the burner or trap
excessive heat in the control area. This can melt control knobs, wiring, or igniters, and increase the risk of
personal injury. Such damage is specifically excluded from our warranty.
PRECAUTIONS - BEFORE YOU USE YOUR SIDE BURNER
(continued)
background
©2018 Hestan Commercial Corporation
6
EN
24. Grease is extremely flammable. Let hot grease cool before attempting to handle or dispose of it. Avoid
letting excessive grease deposits collect by cleaning the burner bowl often. Never clean while the side
burner is on, or hot from recent use.
25. Cooking excessively fatty meats and oils will cause flare-ups or grease fires. Damage caused by them or by
the side burner being left unattended, are not covered under the terms and conditions of our warranty.
26. Only certain types of glass, heatproof glass-ceramic, earthenware, or other glazed utensils are suitable for
side burner use. However, these types of materials may break with sudden temperature changes. Use only
on low or medium heat settings, and according to their manufacturers’ directions.
27. Do not repair or replace any part of the side burner unless specifically recommended in this manual. All
other warranty and non-warranty service should be referred to and performed by a qualified technician.
28. For proper lighting and performance of the burners, keep the ports clean. It is necessary to clean them
periodically for optimum performance. The burners will operate only in one position and must be
mounted correctly for safe operation. See BURNER ADJUSTMENT section of this manual.
29. Clean the side burner with caution. Avoid steam burns - do not use a wet sponge or cloth to clean the
side burner while it is hot. Some cleaners produce noxious fumes or can ignite when applied to a hot
surface. Be sure all side burner controls are turned off and the appliance is cool before using any type
of aerosol cleaner on or around the appliance. The chemical that produces the spraying action could, in
the presence of heat, ignite or cause metal parts to corrode. Clean and perform general maintenance on
the side burner twice a year. Watch for corrosion, cracks, or insect activity. See the CLEANING AND
MAINTENANCE section of this manual.
PRECAUTIONS - BEFORE YOU USE YOUR SIDE BURNER
(continued)
background
©2018 Hestan Commercial Corporation
7
EN
REGULATORY / CODE REQUIREMENTS
Installation of this cooking appliance must be made in accordance with local codes. In the absence of
local codes, this unit should be installed in accordance with the National Fuel Gas Code
ANSI Z223.1/
NFPA 54
, Natural Gas and Propane Installation code
CSA B149.1
, or Propane Storage and Handling Code
B149.2
.
All Electrical Components must be electrically grounded in accordance with local codes or in the absence
of local codes with the National Electrical Code
ANSI/NFPA 70
, or Canadian Electrical code
CSA C22.1
.
STATE OF MASSACHUSETTS
Massachusetts requires all gas be installed using a plumber or gas fitter carrying the appropriate
Massachusetts license. All permanently installed natural gas or propane installations require a T handle
type manual gas valve be installed in the gas supply line to this appliance. This does not apply to portable
propane installations using a 20lb. cylinder.
CALIFORNIA PROPOSITION 65 - WARNING
The burning of gas cooking fuel generates toxic by-products, which are on the list of substances which
are known by the State of California to cause cancer or reproductive harm. California law requires
businesses to warn customers of potential exposure to such substances. To minimize exposure to these
substances, always operate this unit according to the use and care manual, ensuring you provide good
ventilation when cooking with gas. This warning is issued pursuant to California Health & Safety Code
Sec. 25249.6.
PORTABLE LP GAS CYLINDERS
Use only a standard 20 lb. (9.1kg) liquid propane (LP) gas cylinder - 12.25” diam. X 18.25” H
(31cm X 47cm) which features an Overfill Protection Device. The cylinder must be installed in the
upright position. Do not use a dented or rusty LP cylinder as it may be hazardous and should be checked
by your LP supplier. Never use a cylinder with a damaged valve. Never move or alter the gas fittings.
Check the expiration date on the cylinder collar as well. Do not refill an expired cylinder, it must be
replaced. If you buy refilled (exchange) LP cylinders, check this date as well.
The LP gas cylinder must be constructed and marked in accordance with the specifications for LP gas
cylinders of the U.S. Department of Transportation (DOT). The cylinder must be provided with a shut off
valve terminating in an LP gas supply cylinder valve outlet specified, as applicable, for connection type
QCC1 in the standard for compressed gas cylinder valve outlet and inlet connections ANSI/CGA-V-I.
Certain liquid propane dealers may fill LP cylinders for use in the grill / side burner beyond cylinder
filling capacity. This “overfilling” may create a dangerous condition due to a build-up of excess pressure.
As a safety device, there is a pressure relief valve which will vent propane gas vapor to relieve this excess
pressure. This vapor is combustible and therefore can be ignited. To reduce this danger, you should take
the following safety precautions:
1. When you have your cylinder filled, be sure you tell the supplier to fill it to no more than 80% of its
total capacity.
2. If you own or use a spare cylinder, you should NEVER store it near or under the grill/cart unit or
burner box, or near any other ignition or heat source (like a water heater or furnace).
IF THE INFORMATION IN 1 AND 2 ABOVE IS NOT FOLLOWED EXACTLY, A FIRE CAUSING
DEATH OR SERIOUS INJURY MAY OCCUR.
3. The LP cylinder must be disconnected and stored OUTSIDE in a well-ventilated area, out of the reach
of children.
4. Do not store a full cylinder in direct sunlight.
background
©2018 Hestan Commercial Corporation
8
EN
When determining a suitable location for your side burner, take into account concerns such as
exposure to wind, rain, sprinklers, proximity to traffic paths, and keeping any gas supply line runs as
short as possible.
Locate the side burner only in a well-ventilated area. Never locate the side burner in a building, garage,
breezeway, shed or other such enclosed areas without an approved ventilation system. Never locate the
side burner over, under, or next to unprotected combustible construction.
Using the side burner in windy areas can disrupt the flame, especially on low or simmer settings. This
may cause nuisance sparking of the igniter. Relocate to a less windy area. If the side burner is mounted
in an enclosure (island), you may need to build a wind-break to avoid this issue in the future.
When installing a side burner or other gas appliance into an enclosure (island), the enclosure must be
constructed with ventilation openings to avoid accumulation of gas should there be a leak. See the
INSTALLATION section of this manual for details. Keep the area underneath the side burner free of
debris.
Ensure all packaging, straps, etc. have been removed from the side burner. Remove any tie-down wires
from the burners.
Keep the area underneath the side burner free of debris.
Ensure that the burner cap is mounted correctly on the
burner ring. Do not operate the side burner without the
burner cap in place (see Fig. 1).
IGNITER
BURNER PORTS
SIMMER RING
BURNER CAP
Figure 1
INSTALLATION
CLEARANCES - NON-COMBUSTIBLE:
TO NON-COMBUSTIBLE CONSTRUCTION ABOVE THE COOKING SURFACE
A minimum of 4” (10 cm) clearance from the rear of the appliance to non-combustible construction is
required. See diagrams on the following pages.
TO NON-COMBUSTIBLE CONSTRUCTION BELOW THE COOKING SURFACE
The appliance may installed directly on non-combustible construction. See diagrams on the following
pages.
CLEARANCES - COMBUSTIBLE:
TO COMBUSTIBLE CONSTRUCTION ABOVE THE COOKING SURFACE
A minimum of 12” (30 cm) clearance on the sides and the rear of the appliance to combustible construction
is required. Read warning below. See diagrams on the following pages.
TO COMBUSTIBLE CONSTRUCTION BELOW THE COOKING SURFACE
The appliance may installed directly on combustible construction. See diagrams on the following pages.
The minimum clearances to combustible materials means that ALL combustible materials must be outside
this 12” (30 cm) zone. As an example, if you have an island with a stucco or tiled surface and wood-frame
construction, the wood is considered combustible, even though the side burner is touching the stucco
or tile surface, which is non-combustible. In extreme circumstances, the wood could potentially get hot
LOCATING AND ASSEMBLING THE SIDE BURNER
background
©2018 Hestan Commercial Corporation
9
EN
BUILT-IN DIMENSIONS (NON-COMBUSTIBLE):
INSTALLATION
(continued)
enough to burn. Examples of other combustible materials are compressed wood, plant fibers (bamboo),
vinyl/plastic, or other materials capable of being ignited and burned. Materials that are flame-proofed or
treated with flame-retardant are still considered combustible.
VENTILATION OPENINGS
A minimum of three 10 in² (65 cm²) of ventilation openings must be provided for both left and right sides
of your enclosure (island), as well as the back. These openings are required to safely dissipate gas vapors if
there is a leak in your enclosure.
background
©2018 Hestan Commercial Corporation
10
EN
INSTALLATION
(continued)
BUILT-IN DIMENSIONS (COMBUSTIBLE):
background
©2018 Hestan Commercial Corporation
11
EN
GAS SUPPLY
The local gas authority or supplier should be consulted at the installation planning stage in order to
establish the availability of an adequate supply of gas (NG or LP). If it is a new installation, have the
gas authorities or supplier check the meter size and piping to assure that the unit is supplied with the
necessary amount of gas supply and pressure to operate the unit(s).
Gas connections should be made by a qualified plumber, or your professional outdoor appliance installer.
All fixed (non-mobile) appliances must be fitted with an accessible upstream gas shutoff valve as a means of
isolating the appliance for emergency shut off and for servicing.
Make certain new piping and connections have been made in a clean manner and have been purged so that
piping compound, chips, etc. will not clog regulators, valves, orifices, or burners. Use pipe joint compound
/ thread sealant approved for natural and LP gases.
NEVER CONNECT THE SIDE BURNER TO AN UNREGULATED GAS SUPPLY. Before proceeding,
ensure the appliance is fitted for Natural or Liquid Propane gas. Connecting to an improper gas type will
result in poor performance and increased risk of damage or injury. Gas type and gas consumption (BTU
per hour) for each burner type is located on inner right wall of the unit, behind the control panel.
Installation of this cooking appliance must be made in accordance with local codes. In the absence of local
codes, this unit should be installed in accordance with the National Fuel Gas Code No.
Z223.1/ NFPA 54
,
Natural Gas and Propane Installation code
CSA B149-1,
or Propane Storage and Handling Code
B149.2.
NOTE: See rating label for manifold pressure for the type of gas of your appliance.
CONVERSION KITS
Gas conversion kits are available from your Hestan dealer should you need to convert an LP unit to NG, or
vice-versa.
HIGH ALTITUDE KITS
If you live in a high altitude area, 2,000 ft. (610 m) or more above sea level, your side burner will require
different orifices for proper combustion and performance. High altitude kits are available through Hestan
Customer Service. Please have your model and serial number information ready when you call.
GAS AND ELECTRICAL CONNECTIONS
background
©2018 Hestan Commercial Corporation
12
EN
GAS CONNECTION - NATURAL GAS (NG)
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply pressure
is adequate. Use only the gas pressure regulator supplied with this appliance. This regulator is set for
a supply pressure of 7 inch WC (1.74 kPa) to maintain 4 inch WC (1.00 kPa) outlet (manifold) pressure.
Use a minimum 1/2” ID flex hose to prevent gas starvation. Ensure that the service pipe supplying the
side burner is fitted with a shut-off valve conveniently positioned and easily accessible as an emergency
gas shut-off.
Your side burner for use with Natural Gas is supplied with its own regulator which MUST be installed.
If this regulator needs to be replaced, use only the type specified by Hestan for this appliance.
TO CONNECT THE REGULATOR / HOSE ASSEMBLY FOLLOW THE NEXT STEPS:
1. Locate the regulator mounted underneath your side burner.
2. Connect gas supply using a minimum 1/2” diameter flexible (semi–rigid) stainless steel gas hose, no
more than 48” (1.22m) in length. If you plan to inter-connect the side burner with your Aspire Grill,
be sure to use the appropriate fittings and a flexible hose as short as possible to make the connection.
The hose as well as the connectors must comply with the
Standard for Connectors for Outdoor Gas
Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation.
Use the appropriate thread sealant on all connections.
3. Proceed to LEAK TESTING section.
1/2” ID FLEX HOSE,
ELBOW & NIPPLE
(SUPPLIED BY
CUSTOMER)
NAT GAS
REGULATOR
INCOMING
NAT GAS SUPPLY
SHUTOFF VALVE
(SUPPLIED BY
CUSTOMER)
ASPIRE SIDE BURNER
(MODEL AEB122-NG SHOWN)
GAS AND ELECTRICAL CONNECTIONS
(continued)
background
©2018 Hestan Commercial Corporation
13
EN
GAS CONNECTION - LP PIPED SYSTEMS
An LP piped system is one with a large central LP tank that feeds an entire household. These systems
are normally equipped with a high pressure regulator by the large LP tank, and low pressure regulators
close to the home. The gas line connectors must comply with the
Standard for Connectors for Outdoor
Gas Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation.
The connection shall be 48” (1.22 m) or less.
NOTE: To ensure proper heating performance of this appliance, verify that the gas line supply pressure
is adequate. The regulator must be set for a supply pressure of 11 inch WC (2.74 kPa) to maintain 10 inch
WC (2.49 kPa) outlet (manifold) pressure. Use a minimum 1/2” ID flex hose to prevent gas starvation.
Ensure that the service pipe supplying the Side Burner is fitted with a shut-off valve conveniently
positioned and easily accessible as an emergency gas shut-off.
Your Aspire Side Burner for use with an LP Piped System is supplied with its own convertible regulator
which MUST be installed. If this regulator needs to be replaced, use only the type specified by Hestan
for this appliance.
To connect the regulator follow the next steps:
1. Locate the regulator mounted underneath your Side Burner.
2. Connect gas supply using a minimum 1/2” diameter flexible (semi–rigid) stainless steel gas hose, no
more than 48” (1.22 m) in length. If you plan to inter-connect the side burner with your Aspire Grill,
be sure to use the appropriate fittings and a flexible hose as short as possible to make the connection.
The hose as well as the connectors must comply with the
Standard for Connectors for Outdoor Gas
Appliances and Manufactured Homes, ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation.
Use the appropriate thread sealant on all connections.
3. Proceed to LEAK TESTING section.
GAS AND ELECTRICAL CONNECTIONS
(continued)
1/2” ID FLEX HOSE,
ELBOW & NIPPLE
(SUPPLIED BY
CUSTOMER)
CONVERTIBLE
LP GAS
REGULATOR
INCOMING
LP GAS SUPPLY
SHUTOFF VALVE
(SUPPLIED BY
CUSTOMER)
ASPIRE SIDE BURNER
(MODEL AEB122-LP SHOWN)
background
©2018 Hestan Commercial Corporation
14
EN
GAS CONNECTION - LIQUID PROPANE (LP) CYLINDER
Should you wish to connect your Aspire Side Burner to a standard 20 lb. LP gas cylinder, you will need to
order kit AGCKLPT. This kit includes a two-stage regulator/hose assembly for connection to the tank,
and a tank retention device. This regulator/hose assembly must be used WITHOUT alteration. If this
assembly needs to be replaced, contact your Hestan dealer for genuine replacement P/N 014309.
NOTE: To ensure proper heating performance of this appliance, verify that the supply pressure is
adequate. Use only the gas pressure regulator supplied with this appliance. This regulator is set for a
supply pressure of 11 inch WC (2.74 kPa) to maintain 10 inch WC (2.49 kPa) outlet (manifold) pressure.
TO CONNECT THE REGULATOR / HOSE ASSEMBLY FOLLOW THESE STEPS:
1. Locate the regulator and gas connection point in the rear right side of your side burner.
2. Connect the 3/8” Flare (compression flare fitting) X 1/2” NPT female adapter as shown. Then connect
the regulator/hose assembly to the adapter as shown. Use appropriate thread sealant on all connections.
3. Connect the regulator/hose assembly to a standard 20 lb. LP cylinder. The hose as well as the connectors
must comply with the
Standard for Connectors for Outdoor Gas Appliances and Manufactured Homes,
ANSI Z21.75 • CSA 6.27
, and suitable for outdoor installation. Use the appropriate thread sealant on all
connections.
4. Proceed to LEAK TESTING section.
GAS AND ELECTRICAL CONNECTIONS
(continued)
2-STAGE LP
REGULATOR /
HOSE ASSEMBLY
20 lb. LP TANK
(SUPPLIED BY
CUSTOMER)
ELBOW & NIPPLE
(SUPPLIED BY CUSTOMER)
ASPIRE SIDE BURNER
(MODEL AEB122-LP SHOWN)
ADAPTER, 3/8 FLARE
X 1/2 NPT FEMALE
(SHIPPED LOOSE)
RETENTION
DEVICE
(SHIPPED LOOSE)
background
©2018 Hestan Commercial Corporation
15
EN
LEAK TESTING
GENERAL
Although all gas connections on your Aspire side burner are leak tested at the factory prior to shipment,
a complete gas tightness check must be performed at the installation site due to possible movement in
shipment, or excessive pressure unknowingly being applied to parts of the unit. Periodically check the
whole system for leaks, or immediately check if the smell of gas is detected.
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.
TO TEST
Make sure all control valves are in the “OFF” position.
Apply the soap solution described above to all fittings.
Turn the gas supply on.
Check all connections from the supply line, or LP cylinder up to and including the manifold pipe
assembly and all connections to each burner.
Soap bubbles will appear where a leak is present. If a leak is present, immediately turn off gas supply,
tighten any leaking fittings, turn the gas supply back on, and recheck.
If you cannot stop a gas leak, turn off the gas supply and call the dealer where you purchased your side
burner.
Do not use the side burner until all connections have been checked and do not leak.
IMPORTANT NOTE - ALWAYS CHECK FOR LEAKS AFTER EVERY LP CYLINDER CHANGE.
If a leak is present, or if there is evidence of excessive abrasion or wear, or the hose is cut, it must be
replaced before using the side burner. The hose and LP regulator are supplied as a complete assembly and
must be replaced together. Do not attempt to repair or replace the hose itself. Contact your Hestan dealer
for genuine replacement P/N 014309.
Check all gas supply fittings for leaks before each use. It is handy to keep a spray bottle of soapy water near
the shut-off valve of the gas supply line. Spray all the fittings. Bubbles indicate leaks.
ELECTRICAL SUPPLY
Important: This appliance must be electrically grounded in accordance with local codes, or in the absence
of local codes with the National Electrical Code,
ANSI/NFPA 70-1990
.
Appliances equipped with a flexible electrical supply cord are provided with a three-prong grounding
plug. It is imperative that this plug be connected to a properly grounded three-prong receptacle. If the
receptacle is not the proper grounding type, contact an electrician. Do not remove the grounding prong
from this plug.
The side burner is designed for 120 volt AC power and must be plugged into a Ground Fault Circuit
Interrupter (GFCI) protected circuit. Do not connect the side burner to the electrical supply until after
gas connections have been made and leak checks have been performed.
GAS AND ELECTRICAL CONNECTIONS
(continued)
background
©2018 Hestan Commercial Corporation
16
EN
KEEP ANY ELECTRICAL CORD AND FUEL SUPPLY HOSE AWAY FROM ANY HEATED SURFACES.
1. To protect against electric shock, do not immerse cord or plugs in water or other liquid.
2. Unplug from the outlet when not in use and before cleaning. Allow to cool before putting on or taking
off parts.
3. Do not operate any outdoor cooking gas appliance with a damaged cord or plug, or after the appliance
malfunctions or has been damaged in any manner. Contact the manufacturer for repair.
4. Do not let the cord hang over the edge of a table or touch hot surfaces.
5. Do not use an outdoor cooking gas appliance for purposes other than intended.
6. Use only a Ground Fault Circuit Interrupter (GFCI) protected circuit with this outdoor cooking gas
appliance.
7. Never remove the grounding prong or use with a 2-prong ground adapter.
8. Use only extension cords with a 3-prong grounding plug, rated for the power of the equipment, and
approved for outdoor use with a W-A marking.
BURNER ADJUSTMENTS
Aspire side burners are similar to many residential gas cooktops. They do not have any adjustments, except
for the correct orifices, and adjustment of the low setting on the valve.
BURNER FLAME ADJUSTMENT
Each side burner is tested and adjusted at the factory prior to shipment. The proper orifice for the gas
type, and the air-fuel adjustment was made at this time. However, variations in the local gas supply,
the elevation where you live, converting from one gas type to another, and other factors might make it
necessary to adjust the burner flames.
The flames of the burners should be visually checked and
compared with the figures on the right.
Flames should be blue and stable with no yellow tips (LP units
will have some yellow tipping). There should be no excessive
noise or flame lifting. If any of these conditions exist, remove
the burner cap and check if dirt, debris, spider webs, etc., are
blocking the center venturi hole, or the individual burner
ports. The occasional orange flame that quickly goes away is
usually a small amount of dust or water condensation which is
burning off - this is normal.
VALVE ADJUSTMENTS
The valves on your Aspire side burner are preset at the factory for optimum performance. However, the
valve also features a low (simmer) adjustment if altitude, low-heat performance, converting from one gas to
another, or other factors indicate an adjustment is needed.
NEVER ADJUST THE BURNER SO LOW THAT IT MAY GO OUT DURING
USE. DO NOT OPERATE THE SIDE BURNER WITH THE LOW HEAT SCREW
REMOVED. GAS CAN ESCAPE AND CAUSE A POTENTIALLY HAZARDOUS
CONDITION.
GAS AND ELECTRICAL CONNECTIONS
(continued)
background
©2018 Hestan Commercial Corporation
17
EN
GAS AND ELECTRICAL CONNECTIONS
(continued)
ADJUSTMENT STEPS:
1. Pull off the “chin” at the base of the control panel, remove control knobs and control panel from the unit.
2. Follow lighting instructions by setting the control knob on “HI” and allow the burner to preheat for 10
minutes.
3. Turn the control knob to “LOW” and wait for the burner temperature to drop and stabilize, about 10
minutes. Attempting adjustment at any setting other than LOW can create a dangerous condition.
4. Insert a small, flat-blade screwdriver into the small screw to the left of the valve stem to begin the
adjustment (see Fig. 2). The screw only has 2-3 complete revolutions of adjustment. After this, the screw
may continue to turn, but is actually coming out of the valve and could result in a gas leak. DO NOT turn
more than 3 revolutions!
5. Turn counter-clockwise very slowly to INCREASE the low flame. The flame will take a few seconds to
respond to the adjustments you are making.
6. Adjust the flame so the burner is still fully lit on all ports, without fluttering or going out. Turn off
the burner and re-light. Check the new low setting once again to assure proper adjustment is reached.
Reattach the control panel, control knobs, and push-on the chin.
Figure 2
background
©2018 Hestan Commercial Corporation
18
EN
LIGHTING INSTRUCTIONS
Aspire side burners feature a spark-ignition system with flame-sensing technology which will relight the
flame should it go out.
The side burner can also be manually lit should that become necessary.
LIGHTING SIDE BURNERS
1. Read Use & Care Manual before lighting. Remove cover during lighting.
2. Stand as far away as possible when lighting.
3. Push and turn selected knob to “HIGH” position. Igniter will spark until flame is established.
4. Once lit, turn knob to desired flame setting. If spark does not occur, check electrical supply.
5. If burner does not light in 5 seconds, turn knob to “OFF” and wait 5 minutes before re-lighting.
6. If burner fails to light, see USE & CARE MANUAL for match lighting instructions.
Note: The flame-sensing technology of the spark igniter will repeatedly spark (clicking sound) until a
flame is established. If you experience nuisance sparking during normal operation of the burner, see the
TROUBLESHOOTING section of this manual.
MATCH LIGHTING INSTRUCTIONS
If a burner will not light after several attempts, it can be lit with a match. When attempting to light
a burner with a match, be sure you selected the correct control knob for that burner. Keep your face
away as far as possible, and pass the lit match through the openings of the cooking grates and position
near the burner ports. Push and turn the control knob to “HIGH” until the burner lights. Repeat this
procedure for each burner if necessary. If the burner does not light in 5 seconds, turn the control knob to
“OFF” and wait 5 minutes before trying again. If the burner will not light after several attempts, see the
TROUBLESHOOTING section of this manual.
background
©2018 Hestan Commercial Corporation
19
EN
Your Aspire Side Burner is a powerful cooking tool that complements your Aspire Grill. DO NOT leave
the side burner unattended while cooking.
COOKING WITH SIDE BURNERS
Use your Aspire Side Burner like you would any residential gas cooktop in your home. Choose the
appropriate pot or pan for the burner. In other words, don’t put a small pot over a large burner. For safety
reasons, control the flame height so that it doesn’t go beyond, or curl up the sides of your pot or pan. This
behavior results in poor heating of the contents of the pan, burnt food on the sides of the pan, wasted fuel,
etc.
CLEANING AND MAINTENANCE
STAINLESS STEEL CARE
Stainless Steel is widely used for catering and residential kitchen equipment because of its strength, its
ability to resist corrosion, and its ease of cleaning. Unfortunately, the metal is often taken for granted and
it is assumed that no problems will arise during its usage. However, some care is required to ensure a long
service life of the side burner.
To maintain the original appearance of your Aspire side burner, a regular cleaning routine should be
carried out using the following guidelines:
1. After use, following the safety precautions detailed earlier in this manual, wipe the appliance with a soft,
damp, soapy cloth and rinse with clean, warm water. This should remove most substances encountered
during the cooking process.
2. For stubborn stains, including burnt-on grease and food-borne deposits, use a multipurpose, non-abrasive,
cream cleanser and apply with a soft damp cloth. Rinse with fresh water, as described above. On no
account should steel wool pads be used unless they are made of stainless steel.
3. Harsh abrasives and metallic scouring materials should not be used for cleaning stainless steel as they will
leave scratch marks in the surface and damage the appearance of the appliance. Likewise, do not use wire
brushes, scrapers or contaminated scouring pads.
4. For those areas with a directional grain, any cleaning with abrasives should be carried out along this grain
direction and not across it.
5. After use, always remove wet cleaning aids (such as cloths, pads, containers) from the surface, to avoid
formation of water marks or stains.
6. If required, dry the appliance after use with a soft dry cloth or towel.
If the preceding guidelines are adhered to, your Aspire side burner should offer excellent life and should
live up to its reputation of being “stainless”. Neglect of this practice, however, can lead to deterioration
of the surface and, in some extreme cases, corrosion of the steel itself. The two most common types of
corrosion that may be encountered, particularly on stainless steel, are rust marks and pitting of the surface.
RUST-BROWN MARKS
These rust marks are likely the result of small particles of “ordinary-steel” which have become attached
to the surface and have subsequently rusted in the damp environment. The most common source of such
particles is from steel wool scouring pads, but contamination may also occur from carbon steel utensils and
old water supply pipes. These brown marks are only superficial stains, which will not harm the side burner.
They should be removable using a soft damp cloth and a multi-purpose, non-abrasive, cream cleanser.
Occasionally, it may be necessary to resort to a proprietary stainless steel cleanser to return the surface of
USING YOUR SIDE BURNER
background
©2018 Hestan Commercial Corporation
20
EN
the side burner to its original condition. To avoid re-occurrence of any “rust-staining”, it is essential that
the source of the contamination is eliminated. An Aspire side burner cover will go a long way toward
preventing this kind of contamination.
PITTING
A more severe form of corrosion is pitting of the surface. The sources of this corrosive attack can usually
be attributed to certain household products such as bleach, household cleaners containing bleach (sodium
hypochlorite), and pool chlorine. If you see pitting of the stainless steel surface, you can attempt to buff it
out using stainless steel abrasive pads, but in most cases, pitting of the surface cannot be removed.
FOODSTUFFS
In general, stainless steel is fully resistant to all foodstuffs in common use. Only in isolated cases, such
as when concentrated salt and vinegar mixtures are allowed to remain in contact with the steel for a
prolonged period, can any surface marking result. Clean the surface as per instructions above.
CARE OF PAINTED SURFACES (IF APPLICABLE)
Aspire side burners are available in standard stainless steel, or 4 optional colors. The tough powder-coating
on these panels are commonly used on automotive parts, and commercial and residential appliances
because of their excellent chip resistance, and resistance to a variety of chemicals. The finish should hold
up well outdoors in most conditions. However, like any painted surface, special care must be taken when
cleaning this finish.
To clean your powder coated surface:
1. Carefully remove any loose deposits with a wet sponge.
2. Use a soft brush (non abrasive) or cloth, and a mild household detergent solution to remove dust, salt
and other deposits. Never use any solvent-based cleaners, stainless steel cleaners, heavy degreasers, oven
cleaners, etc. on the painted surfaces. They can permanently damage the paint.
3. Rinse off with clean fresh water
CARE & MAINTENANCE OF SIDE BURNER COMPONENTS
SIDE BURNER GRATE
The easiest way to clean the cooking grate is immediately after cooking is completed and after turning off
the flame. Wear a grill mitt to protect your hand from the heat and steam. Dip a brass bristle grill brush in
hot soapy water and scrub the hot grate. Dip the brush frequently in the bowl of water. The steam created
as water contacts the hot grate, assists the cleaning process by softening any food particles. If the side
burner is allowed to cool before cleaning, then cleaning will be more difficult.
BURNER CLEANING
Cleaning of the burner assembly itself should only be necessary in the event of a large spillover which may
have clogged the burner ports, etc. When the burner is completely cooled down, remove the burner cap
and clean up whatever debris, food, grease etc. you find using a warm, soapy water solution. A toothbrush
can be used to scrub difficult areas. Wipe with a clean cloth and reassemble.
IGNITERS
The spark igniter on the side burner is partially exposed and can be contaminated in the event you have
a boil-over when using the side burner. You can gently clean them with a soapy water solution and a
toothbrush. Wipe down with a clean cloth.
NOTE: Rough handling of the igniter can crack the ceramic body, causing it to fail. Handle with care.
CLEANING AND MAINTENANCE
(continued)
background
©2018 Hestan Commercial Corporation
21
EN
CLEANING AND MAINTENANCE
(continued)
ADDITIONAL CONSIDERATIONS
Always keep the area around the grill and side burner free of obstructions and debris. Maintain at least
12” (30 cm) of space around the grill and side burner to ensure proper airflow, and keep all ventilation
openings clear and free of debris. Clean appliance after each use, and check for blockages, especially at the
burner orifices, after periods of prolonged non-use. To maintain the appearance of your Aspire side burner
for many years, keep it covered when not in use. Backyard environments are harsh on your appliance’s
finish. Long exposure to sun, water, yard chemicals and the elements could diminish the appearance of the
stainless steel. This is very evident in ocean-front locations.
Our appliance materials have been tested in saline solutions with higher salinity than seawater. They have
also been tested by exposure to highly acidic foods. During and after these tests, we found these materials
were able to withstand exposure over prolonged periods of time. However, the above-mentioned corrosive
substances, along with neglect, can lead to a situation whereby conditions might combine to cause some
damage to occur. Therefore, we suggest that you always keep your grill and side burner clean, dry and
covered when not in use. This is even more important when long term storage is required. Always store
the grill and side burner clean, dry and covered with your Aspire Grill and Side Burner Cover. A dirty
grill and side burner will attract insects and rodents which is highly unsanitary. In addition, rodents are
known to chew on the insulation of wiring which will cause permanent damage to the wiring and possibly
electrical components.
For those in desert communities, wind-driven sand is highly abrasive and constant exposure will eventually
pit and scratch the surface. Another reason to keep your grill and side burner covered when not in use.
background
©2018 Hestan Commercial Corporation
22
EN
TROUBLESHOOTING GUIDE
Symptom Check
Burner will not light Gas supply not on / shutoff valve closed
LP gas cylinder empty
Power cord not plugged in, or no power to receptacle, or blown fuse
Low gas pressure to unit
Burner ports near igniter are obstructed or dirty
Burner cap not installed correctly on base
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Igniter defective (not sparking)
Defective regulator or regulator installed improperly
Burner will not stay lit Burner ports obstructed or dirty
Vent plugged on regulator or regulator installed improperly
Windy conditions
Low gas pressure
Slow to heat up Low gas pressure or low LP cylinder
Burner ports are obstructed or dirty
Defective or clogged burner valve
Incorrect orifice or clogged orifice
Gas Odor Burner went out or did not light
Loose or broken gas line
Ruptured pressure regulator
Burner cap not installed correctly on base
Poor combustion, air-fuel mixture not adjusted properly
Obstructed/dirty burner ports
Burner not working well /
lazy or yellow flame
Burner ports are obstructed or dirty, check for spider webs
Poor combustion, air-fuel mixture not adjusted properly
Gas pressure incorrect / incorrect regulator
Orifice sized incorrectly for gas type
Control panel LED lights not
working
Power cord not plugged in, or no power to receptacle
Check fuse on electrical box.
Nuisance clicking of side
burner
Windy conditions
Flame too low
Food debris on electrode
background
©2018 Hestan Commercial Corporation
23
EN
WIRING SCHEMATIC
ELECTRICAL
BOX SINGLE
background
©2018 Hestan Commercial Corporation
24
EN
WIRING SCHEMATIC
WIRE HARNESS
SINGLE
background
©2018 Hestan Commercial Corporation
25
EN
WIRING SCHEMATIC
ELECTRICAL
BOX DOUBLE
background
©2018 Hestan Commercial Corporation
26
EN
WIRING SCHEMATIC
WIRE HARNESS
DOUBLE
background
©2018 Hestan Commercial Corporation
27
EN
SERVICE
All warranty and non-warranty repairs should be performed by qualified service personnel. To
locate an authorized service agent in your area, contact your Hestan dealer, local representative, or
the manufacturer. Before you call, please have the model number and serial number information
ready. This information is shown on the rating sticker affixed to the inside rear wall of your
appliance.
Hestan Commercial Corporation
3375 E. La Palma Avenue
Anaheim, CA 92806
(888) 905-7463
LIMITED WARRANTY
WHAT THIS LIMITED WARRANTY COVERS
Hestan Commercial Corporation (“HCC”) warrants to the original consumer purchaser of an
Aspire by Hestan outdoor gas product (the “Product”) from an HCC authorized dealer that the
Product is free from defective materials or workmanship for a period of one (1) year from the
date of original retail purchase or closing date for new construction, whichever period is longer
(“Limited Warranty Period”). HCC agrees to repair or replace, at HCC’s sole option, any part or
component of the Product that fails due to defective materials or workmanship during the Limited
Warranty Period. This Limited Warranty is not transferable and does not extend to anyone beyond
the original consumer purchaser (“Purchaser”). This Limited Warranty is valid only on Products
purchased and received from an HCC authorized dealer in the fifty United States, the District of
Columbia and Canada. This Limited Warranty applies only to Products in non-commercial use and
does not extend to Products used in commercial applications.
HOW TO OBTAIN WARRANTY SERVICE
If the Product fails during the Limited Warranty Period for reasons covered by this Limited
Warranty, the Purchaser must immediately contact the dealer from whom the Product was
purchased or HCC at 888.905.7463.
Purchaser is responsible for making the Product reasonably accessible for service or for paying the
cost to make the Product reasonably accessible for service. Service is to be provided during normal
business hours of the authorized Hestan Commercial Service Provider. To the extent Purchaser
requests service outside of the normal business hours of the authorized Hestan Commercial Service
Provider, Purchaser will pay the difference between regular rates and overtime or premium rates.
Purchaser is required to pay all travel costs for travel beyond 50 miles (one way) from the nearest
authorized Hestan Commercial Service Provider.
Please visit the Hestan website to access the parts list for your Aspire by Hestan product:
www.hestanhome.com.
(Continued on the next page)
PARTS LIST
background
©2018 Hestan Commercial Corporation
28
EN
EXTENSIONS TO ONE YEAR LIMITED WARRANTY PERIOD:
In addition to the One-Year Limited Warranty, the following components have extended warranty coverage
as specifically set forth below:
1. The Product’s stainless steel grill body, stainless tubular grill burners, Sear burners and rotisserie
infrared burner (where applicable) are warranted to be free from defects in material and workmanship
under normal non-commercial use and service for the lifetime of the original Purchaser. This excludes
surface corrosion, scratches, and discoloration which may occur during normal use and is limited to
replacement of the defective part(s), with the Purchaser paying all other costs, including labor, shipping
and handling, as applicable.
2. The Product’s cooking grates and warming rack are warranted to be free from defects in material and
workmanship under normal non-commercial use and service, for a period of ten (10) years from the
original date of purchase. This excludes surface corrosion, scratches, and discoloration which may
occur during normal use and is limited to replacement of the defective part(s), with the Purchaser
paying all other costs, including labor, shipping and handling, as applicable.
3. The Product’s spit rod, briquette trays, manifolds, gas valves and sealed burner assemblies (where
applicable) are warranted to be free from defects in material and workmanship, under normal non-
commercial use and service, for a period of five (5) years from the original date of purchase. This is
limited to replacement of the defective parts, with the Purchaser paying all other costs, including labor,
shipping, and handling, as applicable.
4. All other grill components are warranted to be free from defects in material and workmanship,
under normal non-commercial use and service, for a period of two (2) years from the original date of
purchase. This is limited to replacement of the defective parts, with the Purchaser paying all other costs,
including labor, shipping, and handling, as applicable.
WHAT THIS LIMITED WARRANTY DOES NOT COVER:
This Limited Warranty does not cover and HCC will not be responsible for and will not pay for: damage to
or defects in any Product not purchased from an HCC authorized dealer; color variations in color finishes
or other cosmetic damage; failure or damage from abuse, misuse, accident, fire, natural disaster, commercial
use of the Product, or loss of electrical power or gas supply to the Product; damage from alteration,
improper installation, or improper operation of the Product; damage from improper or unauthorized
repair or replacement of any part or component of the Product; damage from service by someone other
than an authorized agent or representative of the Hestan Commercial Service Network; normal wear and
tear; damage from exposure of the Product to a corrosive atmosphere containing chlorine, fluorine, or any
other damaging chemicals; damage resulting from the failure to provide normal care and maintenance to
the Product; damage HCC was not notified of within the Limited Warranty Period; and incidental and
consequential damages caused by any defective material or workmanship.
ARBITRATION:
This Limited Warranty is governed by the Federal Arbitration Act. Any dispute between Purchaser
and HCC regarding or related to the Product or to this Limited Warranty shall be resolved by binding
arbitration only on an individual basis with Purchaser. Arbitration will be conducted by the American
Arbitration Association (“AAA”) in accordance with its Consumer Arbitration Rules or by JAMS. The
arbitration hearing shall be before one arbitrator appointed by the AAA or JAMS. The arbitrator shall not
conduct class arbitration and Purchaser shall not bring any claims against HCC in a representative capacity
on behalf of others.
LIMITED WARRANTY
(continued)
background
©2018 Hestan Commercial Corporation
29
EN
LIMITATION OF LIABILITY:
This Limited Warranty is the final, complete and exclusive agreement between HCC and Purchaser
regarding the Product.
THERE ARE NO EXPRESS WARRANTIES OTHER THAN THOSE LISTED AND DESCRIBED
ABOVE. NO WARRANTIES WHETHER EXPRESS OR IMPLIED, INCLUDING, BUT NOT
LIMITED TO, ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A
PARTICULAR PURPOSE SHALL APPLY AFTER THE LIMITED WARRANTY PERIOD STATED
ABOVE. NO OTHER EXPRESS WARRANTY OR GUARANTY GIVEN BY ANY PERSON, FIRM
OR CORPORATION WITH RESPECT TO THIS PRODUCT SHALL BE BINDING ON HCC. HCC
ASSUMES NO RESPONSIBILITY THAT THE PRODUCT WILL BE FIT FOR ANY PARTICULAR
PURPOSE, EXCEPT AS OTHERWISE PROVIDED BY APPLICABLE LAW.
HCC SHALL NOT BE LIABLE FOR LOSS OF REVENUE OR PROFITS, FAILURE TO REALIZE
SAVINGS OR OTHER BENEFITS, OR ANY OTHER SPECIAL, INCIDENTAL OR CONSEQUENTIAL
DAMAGES CAUSED BY THE USE, MISUSE OR INABILITY TO USE THE PRODUCT, REGARDLESS
OF THE LEGAL THEORY ON WHICH THE CLAIM IS BASED, AND EVEN IF HCC HAS BEEN
ADVISED OF THE POSSIBILITY OF SUCH DAMAGES. NO RECOVERY OF ANY KIND AGAINST
HCC SHALL BE GREATER IN AMOUNT THAN THE PURCHASE PRICE OF THE PRODUCT.
WITHOUT LIMITING THE FOREGOING, YOU ASSUME ALL RISK AND LIABILITY FOR
LOSS, DAMAGE OR INJURY TO YOU AND YOUR PROPERTY AND TO OTHERS AND THEIR
PROPERTY ARISING OUT OF THE USE, MISUSE OR INABILITY TO USE THE PRODUCT NOT
CAUSED DIRECTLY BY THE NEGLIGENCE OF HCC. THIS LIMITED WARRANTY STATES YOUR
EXCLUSIVE REMEDY.
No oral or written representation or commitment given by anyone, including but not limited to, an
employee, representative or agent of HCC will create a warranty or in any way increase the scope of this
express Limited One Year Warranty. If there is any inconsistency between this Limited Warranty and any
other agreement or statement included with or relating to the Product, this Limited Warranty shall govern.
If any provision of this Limited Warranty is found invalid or unenforceable, it shall be deemed modified
to the minimum extent necessary to make it enforceable and the remainder of the Limited Warranty shall
remain valid and enforceable according to its terms.
INTERACTION OF LAWS WITH THIS LIMITED WARRANTY:
Some states, provinces or territories may not allow limitations on how long an implied warranty lasts or
the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions
may not apply to you. Some states, provinces or territories may provide for additional warranty rights and
remedies, and the provisions contained in this Limited Warranty are not intended to limit, modify, take
away from, disclaim or exclude any mandatory warranty requirements provided by states, provinces or
territories, including certain implied warranties. This warranty gives you specific legal rights, and you may
also have other rights which vary depending on location.
Any questions about this Limited Warranty may be directed to
Hestan Commercial Corporation at (888) 905-7463
LIMITED WARRANTY
(continued)
background
Hestan Commercial Corporation
3375 E. La Palma Ave.
Anaheim, CA 92806
(888) 905-7463
RETAIN THIS MANUAL FOR FUTURE REFERENCE
CONSERVEZ CE MANUEL POUR UNE RÉFÉRENCE FUTURE
©2018 Hestan Commercial Corporation P/N 015309 REV C

Specifications